Loading...
HomeMy WebLinkAbout2026/01/21 - ADMIN - Agenda Packets - Planning Commission - Regular Planning commission meeting January 21, 2026 6:00 p.m. If you need special accommodations or have questions about the meeting, please call Sean Walther at 952.924.2574 or the administration department at 952.924.2525. Planning commission meeting and study session The St. Louis Park Planning Commission is meeting in person at St. Louis Park City Hall, 5005 Minnetonka Blvd. Members of the public can attend the planning commission meeting in person or watch the regular meeting by webstream at www.parktv.org and on local cable (Comcast SD channel 14 and HD channel 798). Visit bit.ly/slppcagendas to view the agenda and reports. You can provide comment on agenda items in person at the meeting or by emailing your comments to info@stlouispark.org by noon the day of the meeting. Comments must be related to an item on the meeting agenda. Agenda PLANNING COMMISSION MEETING 1. Call to order – roll call 2. Approval of minutes – January 7, 2026 3. Hearing 3.a. Application name: Park Community Church conditional use permit Location: 6805 Minnetonka Blvd. Applicant: Park Community Church Case No: 25-08-CUP 3.b. Application name: Parkway on 5 preliminary and final plat, and variance Location: 5430 Minnetonka Blvd. Applicant: Sela Investments, Ltd., LLP Case No: 25-10-S, 25-11-VAR 4. Other Business 5. Communications 6. Adjournment PLANNING COMMISSION STUDY SESSION 1. Zoning code update, phase 2 – parking standards Future scheduled meeting/event dates: February 4, 2026 – planning commission regular meeting February 25, 2026 – planning commission regular meeting* March 4, 2026 – planning commission regular meeting March 25, 2026 – planning commission regular meeting** *meeting held on Feb. 25, 2026 since Ash Wednesday is Feb. 18, 2026. ** meeting held on March 25, 2026 since Eid-a-Fitr potentially begins March 18, 2026 1 2 Unofficial Minutes Planning commission St. Louis Park, Minnesota January 7, 2026 1. Call to order – 6:00 p.m. Roll Call Members present: Jim Beneke, Mia Divecha (arrived at 6:01 p.m.), Matt Eckholm, John Flanagan, Sylvie Hyman, Tess Machalek, Sarah Strain Members absent: Tom Weber Guests: Joanna Griffith, Pope Design Group Nate Enger, Kraus-Anderson Pastor Andrew Peterson, Park Community Church Edgar Durand, North Central State Regional Council of Carpenters Staff present: Katelyn Champoux, Sean Walther 2. Approval of Minutes – Oct. 8, 2025; Oct. 15, 2025; Nov. 5, 2025 and Dec. 3, 2025. It was moved by Commissioner Beneke, seconded by Commissioner Hyman to approve the Oct. 8, 2025, Oct. 15, 2025, Nov. 5, 2025 and Dec. 3, 2025 minutes. The motion passed 6-0. 3. Hearing 3a. Title: Park Community Church conditional use permit Location: 6805 Minnetonka Blvd. Applicant: Park Community Church Case No: 25-08-CUP Ms. Champoux presented the conditional use permit application for Park Community Church, located at 6805 Minnetonka Boulevard. She explained that staff recommended opening the public hearing but tabling the item until the Jan. 21, 2026 meeting because of an error in the public hearing notice that was mailed to property owners, which listed the incorrect date. A new notice with the correct date was mailed on Jan. 6. Ms. Champoux provided details about the project, explaining that the church proposed to renovate the interior of the sanctuary and community spaces, expand the sanctuary by approximately 500 square feet on the south side of the building (on top of an existing mechanical roof), and remove existing pavement on the north and west sides of the building to replace it with green space. The purpose was to provide more space for the existing congregation and improve accessibility, comfort, and functionality without altering the building's character. She noted that the zoning code requires a conditional use permit for religious institutions in the N-2 zoning district. Although the church's establishment predated this requirement, the proposed site work required the church to come into compliance with city code. 3 Unofficial minutes January 7, 2026 Planning commission Ms. Champoux discussed how the project would remove a significant portion of impervious surface, replacing it with green space and removing two access points onto Minnetonka Boulevard. The planned landscaping would bring the site into compliance with city code, adding 30 trees and 172 shrubs while preserving all existing trees. This would reduce impervious surface coverage from about 75% to 59%. Regarding parking, Ms. Champoux explained that the project would increase sanctuary capacity from approximately 215 to 344 seats, resulting in a parking requirement of 98 spaces (after applying a 15% transit reduction). The church proposed providing 60 off-street parking spaces with 12 potential additional spaces through "proof of parking," plus 13 street parking spaces adjacent to the property. The church requested a reduction of 13 parking spaces to its requirement, which would change the requirement from 98 to 85 spaces. Ms. Champoux noted that the project would also bring the site into compliance with the city's electric vehicle charging infrastructure ordinance and bike parking ordinance, providing 4 parking spaces with EV chargers, 28 spaces with conduit for future chargers, and 12 bike parking spaces (double the requirement). She reported that the project team held a neighborhood meeting on Dec. 3, 2025 with one resident attending who shared general concerns about street parking but did not oppose the project. Commissioner Divecha asked for clarification about the driveway access changes. Ms. Champoux explained that the property currently has five access points and the project would remove two access points on Minnetonka Boulevard and one on Hampshire Avenue South. Commissioner Hyman inquired about the existing shared parking agreement between the church and the community center. Ms. Champoux explained that the informal agreement did not meet city requirements because shared parking agreements need to be permanent and recorded against the property. Commissioner Hyman also asked about bicycle parking plans. Ms. Griffith from Pope Design Group responded that while the specific bike rack design had not been selected, they planned to install functional racks that would exceed the minimum requirement by providing 12 spots instead of the required six. Commissioner Beneke asked if removing parking spots was necessary for the new sanctuary. Mr. Enger from Kraus-Anderson explained that reducing impervious surface helped avoid the need for expensive underground stormwater storage, as there is no stormwater infrastructure currently in that section of Minnetonka Boulevard, which is slated for improvements next fiscal year. He added that the church also desired more green space. Mr. Peterson, Pastor at Park Community Church and St. Louis Park resident, expressed excitement about bringing the historic building up to current code and improving its function for the city and community. He noted that the church, established in 1945, had nearly closed 4 Unofficial minutes January 7, 2026 Planning commission about a decade ago but had been revitalized with a growing congregation that includes many St. Louis Park residents who walk and bike from surrounding neighborhoods. Mr. Durand, a business agent with the North Central State Regional Council of Carpenters, expressed thanks to the Kraus-Anderson team for providing work opportunities for union members. It was moved by Commissioner Strain, seconded by Commissioner Eckholm, to table the Park Community Church CUP and continue the public hearing at the Jan. 21, 2026 meeting. The motion passed 6-0. 4. Other Business 4a. 2026 Work Plan Mr. Walther presented the 2026 work plan that the commission had crafted last year and presented to the city council in November 2025. He explained that the council had asked all boards and commissions to formally approve their recommended plans and council would also review and approve the plans. Mr. Walther outlined the key components of the work plan:  Reviewing planning applications and holding public hearings  Continuing work on phase 2 of the zoning code update, focusing on business district standards, the zoning map for commercial districts, and performance standards  Implementing approved plans for light rail stations and West Excelsior Boulevard  Beginning the 2050 comprehensive plan process, which would be a 2-3 year effort  Broadening participation in planning processes, including the recently implemented stipend for commissioners to reduce barriers to service Mr. Walther explained that if commissioners wanted to propose additions to the work plan during the year, they would need to submit a form to staff, which would then be brought to the commission for discussion and potentially forwarded to the city council for approval. Commissioner Divecha expressed interest in adding a study on parking to the work plan, following up on a discussion from the previous meeting. Mr. Walther agreed to send the form to commissioners. It was moved by Commissioner Divecha, seconded by Commissioner Eckholm to approve the 2026 work plan as proposed by staff. The motion passed 6-0. 5. Communications Future scheduled meeting/event dates:  January 21, 2026 – planning commission regular meeting  February 4, 2026 – planning commission regular meeting  February 25, 2026 – planning commission regular meeting*  March 4, 2026 – planning commission regular meeting *meeting held on Feb. 12, 2026 since Ash Wednesday is Feb. 18, 2026. 5 Unofficial minutes January 7, 2026 Planning commission 6. Adjournment – 6:30 p.m. ______________________________________ ______________________________________ Sean Walther, liaison John Flanagan, chair member These minutes were created with the assistance of a generative AI transcript service, then edited by a staff person. 6 Planning commission: Regular meeting Meeting date: January 21, 2026 Agenda item: 3.a. 3.a. Park Community Church conditional use permit Executive summary Location: 6805 Minnetonka Blvd. Case number: 25-08-CUP Applicant: Park Community Church Owner: Park Community Church Review deadline: 60 days: February 9, 2026 120 days: April 10, 2026 Recommended motion: Chair to open public hearing, take testimony, and close public hearing. Motion to recommend approval of a conditional use permit for 6805 Minnetonka Blvd. to allow a religious institution and a reduction of 13 parking spaces. Summary of requests: Park Community Church applied for a conditional use permit to renovate the interior of the sanctuary and community spaces at Park Community Church, expand the sanctuary by approximately 500 square feet on the south side of the building, and remove existing pavement on the north and west sides of the building and replace those areas with green space. The purpose of the project is to provide more space for the existing congregation in the sanctuary and improve accessibility, comfort and functionality without altering the building’s character. The zoning code requires a conditional use permit for religious institutions in the N-2 zoning district. Although the church’s establishment predates this code requirement, the proposed site work requires the church to come into compliance with city code. The zoning code allows city council to revise parking requirements as part of a conditional use permit application. The applicant requests the city council revise the parking requirement downward by 13 parking spaces given excess street parking available adjacent to Lenox Community Center that can be used to accommodate additional parking needs. Lenox Community Center provides 115 off-street parking spaces, which is nearly double the number of parking spaces required for the use. Staff do not anticipate adverse impacts on the adjacent property owners resulting from the parking reduction or the use of street parking along the east side of Hampshire Avenue South. Supporting documents: Site survey, site plan, landscape plan, building elevations, unofficial minutes for Jan. 7, 2026, planning commission meeting Prepared by: Katelyn Champoux, associate planner Reviewed by: Laura Chamberlain, senior planner 7 Regular meeting of January 21, 2026 (Item No. 3.a.) Title: Park Community Church conditional use permit - 6805 Minnetonka Blvd. Discussion Site information: Park Community Church is located at 6805 Minnetonka Blvd. in the Lenox neighborhood. The church was established in 1946 as St. Louis Park Evangelical Free Church, but the church building was not constructed until 1948. The property spans one city block bounded by Minnetonka Boulevard. to the north, Idaho Avenue South to the west, and Hampshire Avenue South to the east. The property contains the 29,000 square foot church and a 1,600 square foot parish house in the northwest corner. The project does not propose changes to the existing parish house. Site area (acres) 1.5 acres Building area (sq ft) 28,892 square feet Use Religious institution 2040 Future Land Use CIV – Civic Zoning N-2 Surrounding land uses North: Single-unit dwellings East: Community center South: Single-unit dwellings West: Single-unit dwellings Background: Park Community Church proposes to renovate the interior of the building, complete a minor expansion to the existing sanctuary, and remove excess pavement along the north and west sides of the building to accommodate additional green space. The purpose of the project is to provide more space for the existing congregation in the sanctuary and improve accessibility, 8 Regular meeting of January 21, 2026 (Item No. 3.a) Title: Park Community Church conditional use permit - 6805 Minnetonka Blvd. comfort and functionality without altering the building’s character. The zoning code requires a conditional use permit for religious institutions in the N-2 zoning district. Although the church’s establishment predates this code requirement, the proposed site work requires the church to come into compliance with city code. Present considerations: The applicant requests the city approve a conditional use permit for 6805 Minnetonka Blvd. to allow a religious institution use and consider a reduction of required on-site parking. Zoning analysis: Below is a table summarizing the zoning requirements for this project. Further details on some of the requirements are provided after the table. Factor Required Proposed Met? Use Religious institution Religious institution Yes Height 40 feet (max) 37.5 feet Yes Building Materials Minimum of 60% class 1; No more than 10% class 3 materials North: Class 1 – 90%, Class 3 – 4% South: Class 1 – 64%, Class 3 – 1% West: Class 1 – 92%, Class 3 – 1% East: Class 1 – 91%, Class 3 – 1% Yes Off-Street Parking 98 parking spaces See parking analysis below. Yes EV charging infrastructure EV chargers: 3 parking spaces Conduit for future chargers: 29 parking spaces EV chargers: 4 parking spaces Conduit for future chargers: 28 parking spaces (plus the extra EV charging space) Yes Bicycle parking 6 bicycle parking spaces 12 bicycle parking spaces Yes Setbacks Front: 25 feet Side: 9 feet or 20 feet when adjacent to a property zoned N-1 Rear: 25 feet Front: 34 feet Side: 35 feet, 91 feet Rear: 80 feet Yes Landscaping Trees: 30 Shrubs: 177 Trees: 37 trees (7 existing, 30 new) Shrubs: 180 (8 existing, 172 new) Yes Impervious surface coverage 80% (max) 57% Yes Off-street parking. Parking requirement. The proposed project meets the parking requirement for Park Community Church with the proposed proof of parking and parking reduction. The zoning code requires religious institutions to provide one parking space per three seats. For Park Community Church, this would apply to the capacity of its sanctuary. The floor plan shows 344 seats in the 9 Regular meeting of January 21, 2026 (Item No. 3.a) Title: Park Community Church conditional use permit - 6805 Minnetonka Blvd. sanctuary, which would require 115 parking spaces. The church qualifies for a 15% transit reduction given its proximity to high-frequency bus service at the intersection of Minnetonka Boulevard and Hampshire Avenue South. This reduces the requirement to 98 parking spaces. The proposed site plan indicates the provision of 58 parking spaces in the parking lot, two (2) parking spaces in the parish house driveway, and 13 parking spaces on the street adjacent to the property. The existing church parking lot has 67 parking spaces. Proof of parking. Park Community Church proposes using the proof of parking ordinance in the zoning code to meet a portion of the remaining parking requirement. Proof of parking demonstrates that a property can accommodate the required parking while deferring construction of this additional parking until the zoning administrator or property owner determines necessary. The applicant provided a site plan showing 12 additional proof of parking spaces for a total of 85 parking spaces for the site. Request for reduction. The zoning code allows city council to revise parking requirements as part of a conditional use permit application. The applicant requests the city council revise the parking requirement downward by 13 parking spaces given excess parking available adjacent to Lenox Community Center that can be used to accommodate additional parking needs. Lenox Community Center provides 115 off-street parking spaces, which is nearly double the number of parking spaces required for the use. Given the surplus of off-street parking, staff find it appropriate to assume that Lenox Community Center may not need adjacent street parking to accommodate its parking demand. Staff recommend reducing the parking requirement by 13 parking spaces under the assumption that the street parking available along the east side of Hampshire Avenue South adjacent to Lenox Community Center may accommodate this need. Park Community Church shared that 10 Regular meeting of January 21, 2026 (Item No. 3.a) Title: Park Community Church conditional use permit - 6805 Minnetonka Blvd. these spaces are typically used by church patrons, and it anticipates this would continue after completion of the proposed project. Staff do not anticipate adverse impacts on the adjacent property owners resulting from the parking reduction or the use of street parking along the east side of Hampshire Avenue South. Access. The project proposes to reduce the number of access points to the site from seven to four. The project would remove the two access points to Minnetonka Boulevard on the north side of the site and remove one of the driveways on Hampshire Avenue South. After completion of the project, church patrons may access the site via the driveways off Idaho Avenue South and Hampshire Avenue South or the alley access off Idaho Avenue South. Building materials. The zoning ordinance requires at least 60% class 1 materials, which include materials such as glass and brick, and allows for up to 10% class 3 materials. Although the project does not propose major external changes to the building, the existing building uses less than 5% of class 3 materials on each façade. Height. The height of the building is 37.5 feet. This would not change with the proposed project. The building height meets the zoning code requirement of a maximum of 40 feet. Yards. As noted in the table above, the project complies with all minimum yard requirements for the building. Electric vehicle supply equipment (EVSE). The project proposes electric vehicle charging for four parking spaces including one ADA parking space. It also proposes providing conduit for future EV chargers for 28 parking spaces. This meets the zoning code requirement. Bicycle parking. The zoning code requires six bicycle parking spaces on the site. The proposed project would provide 12 bicycle parking spaces, which exceeds the zoning code requirement. Landscaping. The property requires 30 trees and 177 shrubs. There are seven (7) existing trees on site that will be preserved. The applicant proposes planting 30 new trees for a total of 37 trees on the site and 172 new shrubs on site to add to eight (8) existing shrubs. This meets the landscaping requirement for the property. Conditional use permit analysis: Staff finds the application meets the following general requirements for conditional use permits listed in city code section 36-33(b): 11 Regular meeting of January 21, 2026 (Item No. 3.a) Title: Park Community Church conditional use permit - 6805 Minnetonka Blvd. 1. Consistency with plans. It is consistent with and supportive of principles, goals, objectives, land use designations, redevelopment plans, neighborhood objectives, and implementation strategies of the comprehensive plan. The proposed project aligns with the city’s strategic priority of environmental stewardship by reducing the impervious surface coverage on the site by nearly 11% and adding 30 trees and other landscaping to the site. 2. Nuisance. It is not detrimental to the health, safety, morals, and general welfare of the community. It will not have undue adverse impacts on the use and enjoyment of properties, existing and anticipated traffic conditions, parking facilities on adjacent streets, and values of properties in close proximity to the conditional use. Staff do not anticipate the proposed project will have adverse impacts on the existing and anticipated traffic conditions adjacent to the site. 3. Compliance with code. It is consistent with the regulations, intent and purpose of city code and the zoning district in which the conditional use is located. The proposed use meets the conditions required for religious institutions located in the N-2 zoning district. 4. Consistency with service capacity. It will not have undue adverse impacts on governmental facilities, services or improvements which are either existing or proposed. The proposal is consistent with sewer and water service capacity. 5. Site design. It is consistent with the design and other requirements of site and landscape plans prepared by or under the direction of a professional landscape architect or civil engineer registered in the state and adopted as part of the conditions imposed on the use by the city council. The site design meets these requirements. 6. Consistency with utilities. It is consistent with the city’s stormwater, sanitary sewer, and water plans. The utilities have capacity for the proposed use. Staff find the project meets all general CUP requirements and the specific requirements for religious institutions in the N-2 zoning district. Next steps: The CUP application is tentatively scheduled for city council consideration on Monday, Feb. 2, 2026. Public outreach: A public hearing notice was posted in the Sun Sailor and mailed to property owners within 350 feet of the site. The applicant hosted a neighborhood meeting at Park Community Church on Dec. 3, 2025. One resident attended the neighborhood meeting. The resident shared general concerns about people parking on the street in front of his house but did not oppose the church’s project. He also had some general questions for staff about how the city determines parking requirements. Planning commission: Staff presented the application to the planning commission on Jan. 7, 2026. Due to an error in the mailing notice, staff recommended the planning commission table the agenda item and continue the public hearing at the Jan. 21, 2026 planning commission 12 Regular meeting of January 21, 2026 (Item No. 3.a) Title: Park Community Church conditional use permit - 6805 Minnetonka Blvd. meeting. The planning commission opened the public hearing on Jan. 7, 2026 and received testimony from one person who shared general support for the project. Staff sent a notice for the Jan. 21, 2026 public hearing to neighboring properties on Jan. 6, 2026. Staff recommendation: Staff recommends the following: Motion to recommend approval of a conditional use permit for 6805 Minnetonka Blvd. to allow a religious institution and the reduction of required parking by 13 spaces, with the following conditions: 1. The site shall be developed, used and maintained in accordance with the conditions of the zoning ordinance, approved official exhibits and city code. 2. Construction and staging information will be provided to staff for review and approval before building permits are issued. 3. All new utility service structures shall be buried. 4. Prior to installation of any new signs, the applicant shall submit the necessary sign permits and a site sign plan that shows all existing and proposed signs. No signs will be permitted in public right-of-way. 5. Prior to starting any land disturbing activities, the following conditions shall be met: a. A preconstruction meeting shall be held with the appropriate development, construction, private utility and city representatives. b. All necessary permits shall be obtained. 6. Prior to issuance of building permits, the following conditions shall be met: a. A performance guarantee in the form of cash escrow or irrevocable letter of credit shall be provided to the City of St. Louis Park in the amount of 1.25 times the estimated costs for landscaping. 7. The developer shall comply with the following conditions during construction: a. All city noise ordinances shall be complied with, including that there be no construction activity between the hours of 7 p.m. and 7 a.m. Monday through Friday, and between 7 p.m. and 9 a.m. on weekends and holidays. b. The site shall be kept free of dust and debris that could blow onto neighboring properties. c. Public streets shall be maintained free of dirt and shall be cleaned as necessary. d. The city shall be contacted a minimum of 72 hours prior to any work in a public street. e. Work in a public street shall take place only upon the determination by the city engineer (or designee) that appropriate safety measures have been taken to ensure motorist and pedestrian safety. f. The developer shall install and maintain chain link security fencing that is at least six feet tall along the perimeter of the site. All gates and access points shall be locked during non-working hours. g. Temporary electric power connections shall not adversely impact surrounding neighborhood service. 8. Prior to the issuance of any permanent certificate of occupancy permit the private utilities, site landscaping and irrigation shall be installed in accordance with the official exhibits. 13 Regular meeting of January 21, 2026 (Item No. 3.a) Title: Park Community Church conditional use permit - 6805 Minnetonka Blvd. 9. Upon city approval of and acceptance of private site improvements, the developer shall provide a one-year warranty in the form of a cash escrow or letter of credit for 25% of the final construction costs of the improvements. 10. In addition to any other remedies, the developer or owner shall pay an administrative fee of $750 per violation of any condition of this approval. 11. The proof of parking spaces shall be constructed when determined necessary by the zoning administrator or at such a time as the property owner determines necessary. Any landscaping removed to construct the parking spaces shall be relocated on site to remain compliant with city code. 12. The conditional use permit shall be revoked and cancelled if the use, building or structure for which the conditional use permit is granted is removed or abandoned. 13. Approval of a Building Permit, which may impose additional requirements. 14 6" W M ( P e r R e c . ) 6" W M ( P e r R e c . ) 9" VCP 9" VCP (Per Rec.) 9" VCP (Per Rec.) 12" WM (Per Rec.) 12" WM (Per Rec.) 16 " C I P ( P e r R e c . ) 12 " C I P ( P e r R e c . ) 16 " C I P ( P e r R e c . ) 12 " C I P ( P e r R e c . ) (A P u b l i c R / W ) ALLEY (A Public R/W) 9" V C P N89°18'32"E 267.90 S0 1 ° 0 8 ' 5 7 " E 2 3 0 . 9 8 S89°13'28"W 134.18 S01°05'32"E 22.00 S89°13'27"W 134.20 N0 1 ° 0 2 ' 0 6 " W 2 5 3 . 3 7 ID A H O A V E N U E S O U T H (A P u b l i c R / W ) MINNETONKA BOULEVARD (A Public R/W) HA M P S H I R E A V E N U E S O U T H (A P u b l i c R / W ) Existing House Existing Garage Existing Garage 2 Story Lap Sided House Foundation Area = 1,678 +/- Sq. Ft. Existing House 2 Story Brick Sided Church with Lookout Basement Foundation Area = 13,411+/- Sq. Ft. Co n c r e t e S i d e w a l k Co n c r e t e S i d e w a l k Concrete Sidewalk Concrete Sidewalk Co n c r e t e S i d e w a l k Co n c r e t e S i d e w a l k Concrete Walkway Concrete Walkway Concrete Concrete Concrete Driveway Co n c r e t e W a l k w a y Concrete Steps Concrete Steps W/ Railing Co n c r e t e W a l k w a y Concrete Walkway Concrete Step W/ Railing Concrete Concrete Access Access Access Access Access Truncated Dome Truncated Domes Bike Rack Column Column Column Overhang Overhang Bituminous Parking Lot Bituminous Parking Lot Bituminous Parking Lot Bituminous Drive De c k Wood Step 12 24 9 9 3 6 2 2 Wood Fence [A] Wood Fence Crosses Property Line Wood Fence Keystone Retaining Wall Monument Sign Wood Fence [B] Bituminous Parking Lot Crosses Property Line Rock Pile 88 . 7 17.9 10 . 7 20.8 6. 1 24.5 2. 5 34.0 2. 4 24.4 35 . 8 19.2 39 . 7 1.0 9. 5 18.3 8. 7 61.8 22 . 0 20.0 11 . 6 17.8 3 1 . 2 21.2 19 . 9 7.1 13 . 6 25.8 26 . 3 40.2 1.3 5. 5 1.4 49 . 8 4. 4 Found 1/2 Inch Open Iron Pipe Found 1/2 Inch Open Iron Pipe PID: 1711721120215 Address: 6805 Minnetonka Boulevard PID: 1711721120002 Address: 3029 Idaho Avenue South Owner: Margaret Peltier PID: 1711721120016 Address: 3024 Hampshire Avenue South Owner: Poppenhagen Housing Division Sa n . M a i n EXCEPTION AL L E Y Wat. Serv. (Per Rec.) Concrete Drive Wat. Serv. (Per Rec.) The N Line of the S 2 Feet of Lot 28, Block 5, "Lenox" The N Line of the S 20 Feet of Lot 10, Block 5, "Lenox" DESCRIPTION OF PROPERTY SURVEYED All of Lots 3, 4, 6, 7 and 29, Block 5, "Lenox," according to the recorded plat thereof, Hennepin County, Minnesota, Lot 28, Block 5, "Lenox", except the South 2 feet thereof, according to the recorded plat thereof, Hennepin County, Minnesota, together with that part of the vacated alleys adjacent to said lots 3, 4, 6, 7, 28 and 29. Abstract Property AND All of Lots 1, 2, 5, 8, and 9, and that part of Lot 10 lying North of the South 20.0 feet thereof, "Lenox", according to the plat thereof on file or of record in the office of the Register of Deeds in and for said Hennepin County, together with that part of the vacated alleys adjacent to said lots 1, 2, 5, 8, 9, and 10. Torrens Property GENERAL SURVEY NOTES 1.Bearings are based on the Hennepin County Coordinate System (1986 Adjustment). 2.Elevations are based on the NGVD 29 Datum. Site Benchmark is the top nut of the fire hydrant located in the southeast quadrant at the intersection of Minnetonka Boulevard and Idaho Avenue South, as shown hereon. Elevation = 929.46. 3.We have shown the location of utilities to the best of our ability based on observed evidence together with evidence from the following sources: plans obtained from utility companies, plans provided by client, markings by utility companies and other appropriate sources. We have used this information to develop a view of the underground utilities for this site. However, lacking excavation, the exact location of underground features cannot be accurately, completely and reliably depicted. Where additional or more detailed information is required, the client is advised that excavation may be necessary. Also, please note that seasonal conditions may inhibit our ability to visibly observe all the utilities located on the subject property. ALTA/NSPS LAND TITLE SURVEY NOTES (numbered per Table A) 1.Monuments placed and/or found at all major corners of the boundary of the surveyed property as shown hereon. 2.Site Address: 6805 Minnetonka Boulevard, St. Louis Park, Minnesota 55426. 3.This property is contained in Zone X (area determined to be outside the 0.2% annual chance floodplain) per Flood Insurance Rate Map, Community Panel No. 27053C0353F, effective date of November 4, 2016. 4.The gross land area is 64,936 +/- square feet or 1.491 +/- acres. 7.(a) Exterior dimensions of buildings at ground level as shown hereon. (b)(1) Square footage of exterior footprint of buildings at ground level as shown hereon. 8.Substantial features observed in the process of conducting the fieldwork as shown hereon. Please note that seasonal conditions may inhibit our ability to visibly observe all site features located on the subject property. 9.The number of striped parking stalls on this site are as follows: 58 Regular + 9 Handicap = 67 Total Parking Stalls. 13.The names of the adjoining owners of the platted lands, as shown hereon, are based on information obtained from the Hennepin County Interactive Property Map. SURVEY REPORT 1.This map and report was prepared without the benefit of a Commitment for Title Insurance. The property description was obtained from county tax records and may not be the description of record. There may be easements or other matters of record we are unaware of and thus not shown hereon. 2.Conflicts such as (but not limited to): encroachments, protrusions, access, occupation, and easements and/or servitudes: [A].Wood fence crosses the south line of the subject property, as shown hereon. [B].Bituminous parking lot crosses the south line of the subject property, as shown hereon. ALTA CERTIFICATION To: St Louis Park Evang Free Church: This is to certify that this map or plat and the survey on which it is based were made in accordance with the 2021 Minimum Standard Detail Requirements for ALTA/NSPS Land Title Surveys, jointly established and adopted by ALTA and NSPS, and includes Items 1, 2, 3, 4, 7(a), 7(b)(1), 8, 9, and 13 of Table A thereof. The fieldwork was completed on 10-2-2025. Dated this 8th day of October, 2025. ________________________________________________________ Rory L. Synstelien Minnesota License No. 44565 rory@civilsitegroup.com VICINITY MAP 68 0 5 M i n n e t o n k a B o u l e v a r d St . L o u i s P a r k , H e n n e p i n C o u n t y , M i n n e s o t a 5 5 4 2 6 76 7 N o r t h E u s t i s S t r e e t , S u i t e 1 9 0 , S t . P a u l , M i n n e s t o a 5 5 1 1 4 Po p e D e s i g n G r o u p PR O J E C T PROJECT NO.: 25375.00 COPYRIGHT 2025 CIVIL SITE GROUP INC.c REVISION SUMMARY DATE DESCRIPTION V1.0 ALTA/NSPS LAND TITLE SURVEY .. .. .. .. .. .. N 44565 RORY L. SYNSTELIEN LICENSE NO.DATE I HEREBY CERTIFY THAT THIS SURVEY, PLAN, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. 10-8-2025N CL I E N T Civil Engineering Surveying Landscape Architecture 5000 Glenwood Avenue Golden Valley, MN 55422 civilsitegroup.com 612-615-0060 QA/QC FIELD CREW DRAWN BY REVIEWED BY UPDATED BY MG/BS/TL DS CJ . OVERHEAD UTILITIES GASMAIN SANITARY SEWER STORM SEWER FIBER/COMM. LINE ELECTRIC LINE (RECORD) WATERMAIN ELECTRIC LINE GASMAIN (RECORD) CHAINLINK FENCE LINE Linetype & Symbol Legend CONCRETE SURFACE PAVER SURFACE BITUMINOUS SURFACE GRAVEL/LANDSCAPE SURFACE IRON FENCE LINE GUARDRAIL WATERMAIN (RECORD) SANITARY SEWER (RECORD) STORM SEWER (RECORD) FIBER/COMM. LINE (RECORD) TELEPHONE LINE (RECORD) TELEPHONE LINE SIGN SANITARY MANHOLE STORM MANHOLE CABLE TV BOX TELEPHONE MANHOLE ELECTRIC TRANSFORMER TELEPHONE BOX TRAFFIC SIGNAL GAS METER ELECTRICAL METER WATER MANHOLE WATER VALVE AIR CONDITIONER BOLLARD CATCH BASIN ELECTRIC MANHOLE GAS VALVE FLAG POLE HANDICAP SYMBOL FOUND IRON MONUMENT HYDRANT CAST IRON MONUMENT SET OR TO BE SET IRON MONUMENT FLARED END SECTION POWER POLE UTILITY MANHOLE GUY WIRE CONIFEROUS TREE DECIDUOUS TREE ROOF DRAIN SEWER CLEAN OUT FIRE CONNECTION WELL UTILITY VAULT POST INDICATOR VALVE GAS MANHOLE HAND HOLE FIBER/COMM. MANHOLE MAIL BOX FUEL TANK ELECTRICAL OUTLET SB SOIL BORING LIGHT POLE ACCESS RESTRICTION WOODEN FENCE LINE SATELLITE DISH BUSH/SHRUB 40102001020 SCALE IN FEET ㄵ 6" W M ( P e r R e c . ) 6" W M ( P e r R e c . ) 9" VCP 9" VCP (Per Rec.) 9" VCP (Per Rec.) 12" WM (Per Rec.) 12" WM (Per Rec.) 16 " C I P ( P e r R e c . ) 12 " C I P ( P e r R e c . ) 16 " C I P ( P e r R e c . ) 12 " C I P ( P e r R e c . ) 9" V C P N89°18'32"E 267.90 S0 1 ° 0 8 ' 5 7 " E 2 3 0 . 9 8 S89°13'28"W 134.18 S01°05'32"E 22.00 S89°13'27"W 134.20 N0 1 ° 0 2 ' 0 6 " W 2 5 3 . 3 7 Existing House Existing Garage Existing Garage 2 Story Lap Sided House Foundation Area = 1,678 +/- Sq. Ft. Existing House 2 Story Brick Sided Church with Lookout Basement Foundation Area = 13,411+/- Sq. Ft. Co n c r e t e S i d e w a l k Co n c r e t e S i d e w a l k Concrete Sidewalk Concrete Sidewalk Co n c r e t e S i d e w a l k Co n c r e t e S i d e w a l k Concrete Driveway Co n c r e t e W a l k w a y Concrete Steps Concrete Steps W/ Railing Co n c r e t e W a l k w a y Concrete Step W/ Railing Concrete Access Truncated Dome Truncated Domes Column Column Column Overhang Overhang De c k Wood Step Wood Fence [A] Wood Fence Crosses Property Line Keystone Retaining Wall Monument Sign [B] Bituminous Parking Lot Crosses Property Line Rock Pile 88 . 7 17.9 10 . 7 20.8 6. 1 24.5 2. 5 34.0 2. 4 24.4 35 . 8 19.2 39 . 7 1.0 9. 5 18.3 8. 7 61.8 22 . 0 20.0 11 . 6 17.8 3 1 . 2 21.2 19 . 9 7.1 13 . 6 25.8 26 . 3 40.2 1.3 5. 5 1.4 49 . 8 4. 4 Found 1/2 Inch Open Iron Pipe Found 1/2 Inch Open Iron Pipe PID: 1711721120215 Address: 6805 Minnetonka Boulevard PID: 1711721120002 Address: 3029 Idaho Avenue South Owner: Margaret Peltier PID: 1711721120016 Address: 3024 Hampshire Avenue South Owner: Poppenhagen Housing Division Sa n . M a i n Wat. Serv. (Per Rec.) Wat. Serv. (Per Rec.) 4. 14" DIM HONEY LOCUST TREE 5. 12" DIM HONEY LOCUST TREE 6. 12" DIM HONEY LOCUST TREE 7. 30 FT TALL ARBORVITAE TREE 1.12" DIM HONEY LOCUST TREE 2. 8FT TALL JUNIPER TREE 12. JUNIPER SHRUB 11. JUNIPER SHRUBS 3. 8 FT TALL JUNIPER TREE 9.WEIGELA SHRUB 10. WEIGELA SHRUB 13. JUNIPER SHRUB 14. JUNIPER SHRUB 15. JUNIPER SHRUB 8. JUNIPER SHRUB EV NO PARKINGNO PARKING 5' PARKING SETBACK 30' BLDG. SETBACK 5' P A R K I N G S E T B A C K 5' PARKING SETBACK 5' P A R K I N G S E T B A C K 30 ' B L D G . S E T B A C K 30 ' B L D G . S E T B A C K 30' BLDG. SETBACK 30' BLDG. SETBACK CONSTRUCTION LIMITS CONSTRUCTION LIMITS CONSTRUCTION LIMITS ACCESSIBLE ROUTE ARROW. DO NOT PAINT, FOR CODE REVIEW ONLY, TYP. 24 . 0 7. 7 5.0 26.0 7. 7 10 . 0 5. 0 24 . 0 91.2 35 . 4 34 . 0 6 . 0 6.0 30 . 0 13.0 8. 5 7. 0 18 . 0 12 . 0 12 . 0 18 . 0 3. 0 18 . 0 12 . 0 12 . 0 18 . 0 18 . 0 7. 0 2. 3 6. 0 3' CURB TAPER 7' CURB TAPER 5' CURB TAPER PED RAMP, SEE DETAILS, TYP. 5' CURB TAPER 7' CURB TAPER 3' CURB TAPER 5' TRANSITION B612 TO SURMOUNTABLE CURB MATCH EXISTING MATCH EXISTING CONC. WALK CONC. WALK CONC. VALLEY GUTTER CONC. B612 CURB & GUTTER CONC. RIBBON CURB CONC. B612 CURB & GUTTER CONC. B612 CURB & GUTTER CONC. WALK MATCH EXISTING MATCH EXISTING MATCH EXISTING MATCH EXISTING MATCH EXISTING MATCH EXISTING MATCH EXISTING MATCH EXISTING MATCH EXISTING MATCH EXISTING (6) "HOOP STYLE" BICYCLE RACKS, SURFACE MOUNT PER MANUF. SPECS. 12 SPACES ACCESSIBLE PARKING SPACE, INCL. SIGNAGE, STRIPING AND RAMPS BIT. PVMT., TYP, SEE FINAL GEOTECH FOR THICKNESS CONCRETE COMM. DRIVEWAY, PER CITY STANDARDS PVMT. MARKINGS, TYP 6' WALL TRASH ENCLOSURE AREA, SEE ARCH. CONCRETE COMM. DRIVEWAY, PER CITY STANDARDS ADJUST SANITARY CASTING PER PROPOSED GRADING, SEE SHEET C3.0 TO TOTO TO TO TO TO TO TO TO R5.0 R 2 0 . 0 R 1 0 . 0 R1 0 . 0 R2 0 . 0 R 5 . 0 R5 . 0 R5.0 R 3 . 0 R3 . 0 R 1 7 . 0 R 1 7 . 0 TO 4' DRAINAGE SWALE 8' TAPER CURB. INSURE BACK OF CURB IS WITHIN PROP LIMITS. CONC. SURMOUNTABLE CURB & GUTTER R 3 . 0 R3 . 0 R 5 . 0 R3 . 0 7' CURB TAPER FEV FEV FEV FEV FEV FEV FEVFEVFEVFEVFEVFEVFEVFEVFEVFEVFEVFEVFEVFEV FEV FEV FEVFEV CONCRETE BOLLARD TYP. FEV 14.0 10 . 0 EVEV FEV FEVFEV 8' ALUMINUM FENCE TYP. 4' ALUMINUM FENCE TYP. RIBBON CURB TYP. 3' CURB TAPER TYP. COORDINATE WITH NEIGHBOR ALL SITE WORK TO BE DONE OUTSIDE OF PROPERTY LINE 9.0 8.5 8.5 8.5 EV3.0 5 . 0 Civil Engineering Surveying Landscape Architecture 5000 Glenwood Avenue Golden Valley, MN 55422 civilsitegroup.com 612-615-0060 COPYRIGHT CIVIL SITE GROUP INC.c PR O J E C T 2025 ISSUE/SUBMITTAL SUMMARY DATE DESCRIPTION 10/17/2025 CITY SUBMITTAL 12/1/2025 CITY RESUBMITTAL 12/22/2025 CITY RESUBMITTAL DRAWN BY DK, RB, BN, ZH REVIEWED BY DK, RB PROJECT MANAGER DK PROJECT NUMBER 25375 PA R K C O M M U N I T Y C H U R C H RE N O V A T I O N 68 0 5 M I N N E T O N K A B L V D , S T . L O U I S P A R K , M N 5 5 4 2 6 KR A U S - A N D E R S O N C O N S T R U C T I O N C O . 50 1 S E I G H T S T , M I N N E A P O L I S , M N 5 5 4 0 4 48776 David J. Knaeble LICENSE NO.DATE I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. 12/22/2025 SITE LAYOUT NOTES: SITE PLAN LEGEND: SIGN AND POST ASSEMBLY. SHOP DRAWINGS REQUIRED. HC = ACCESSIBLE SIGN NP = NO PARKING FIRE LANE ST = STOP CP = COMPACT CAR PARKING ONLY PROPERTY LINE CURB AND GUTTER-SEE NOTES (T.O.) TIP OUT GUTTER WHERE APPLICABLE-SEE PLAN BITUMINOUS PAVEMENT CONSTRUCTION LIMITS TO 1.ALL EXISTING UTILITY LOCATIONS SHOWN ARE APPROXIMATE. CONTACT "GOPHER STATE ONE CALL" (651-454-0002 OR 800-252-1166) FOR UTILITY LOCATIONS, 48 HOURS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL REPAIR OR REPLACE ANY UTILITIES THAT ARE DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. 2.CONTRACTOR SHALL VERIFY LOCATIONS AND LAYOUT OF ALL SITE ELEMENTS PRIOR TO BEGINNING CONSTRUCTION, INCLUDING BUT NOT LIMITED TO, LOCATIONS OF EXISTING AND PROPOSED PROPERTY LINES, EASEMENTS, SETBACKS, UTILITIES, BUILDINGS AND PAVEMENTS. CONTRACTOR IS RESPONSIBLE FOR FINAL LOCATIONS OF ALL ELEMENTS FOR THE SITE. ANY REVISIONS REQUIRED AFTER COMMENCEMENT OF CONSTRUCTION, DUE TO LOCATIONAL ADJUSTMENTS SHALL BE CORRECTED AT NO ADDITIONAL COST TO OWNER. ADJUSTMENTS TO THE LAYOUT SHALL BE APPROVED BY THE ENGINEER/LANDSCAPE ARCHITECT PRIOR TO INSTALLATION OF MATERIALS. STAKE LAYOUT FOR APPROVAL. 3.THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION, INCLUDING A RIGHT-OF-WAY AND STREET OPENING PERMIT. 4.THE CONTRACTOR SHALL VERIFY RECOMMENDATIONS NOTED IN THE GEO TECHNICAL REPORT PRIOR TO INSTALLATION OF SITE IMPROVEMENT MATERIALS. 5.CONTRACTOR SHALL FIELD VERIFY COORDINATES AND LOCATION DIMENSIONS & ELEVATIONS OF THE BUILDING AND STAKE FOR REVIEW AND APPROVAL BY THE OWNERS REPRESENTATIVE PRIOR TO INSTALLATION OF FOOTING MATERIALS. 6.LOCATIONS OF STRUCTURES, ROADWAY PAVEMENTS, CURBS AND GUTTERS, BOLLARDS, AND WALKS ARE APPROXIMATE AND SHALL BE STAKED IN THE FIELD, PRIOR TO INSTALLATION, FOR REVIEW AND APPROVAL BY THE ENGINEER/LANDSCAPE ARCHITECT. 7.CURB DIMENSIONS SHOWN ARE TO FACE OF CURB. BUILDING DIMENSIONS ARE TO FACE OF CONCRETE FOUNDATION. LOCATION OF BUILDING IS TO BUILDING FOUNDATION AND SHALL BE AS SHOWN ON THE DRAWINGS. 8.THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OR SAMPLES AS SPECIFIED FOR REVIEW AND APPROVAL BY THE ENGINEER/LANDSCAPE ARCHITECT PRIOR TO FABRICATION FOR ALL PREFABRICATED SITE IMPROVEMENT MATERIALS SUCH AS, BUT NOT LIMITED TO THE FOLLOWING, FURNISHINGS, PAVEMENTS, WALLS, RAILINGS, BENCHES, FLAGPOLES, LANDING PADS FOR CURB RAMPS, AND LIGHT AND POLES. THE OWNER RESERVES THE RIGHT TO REJECT INSTALLED MATERIALS NOT PREVIOUSLY APPROVED. 9.PEDESTRIAN CURB RAMPS SHALL BE CONSTRUCTED WITH TRUNCATED DOME LANDING AREAS IN ACCORDANCE WITH A.D.A. REQUIREMENTS-SEE DETAIL. 10.CROSSWALK STRIPING SHALL BE 24" WIDE WHITE PAINTED LINE, SPACED 48" ON CENTER PERPENDICULAR TO THE FLOW OF TRAFFIC. WIDTH OF CROSSWALK SHALL BE 5' WIDE. ALL OTHER PAVEMENT MARKINGS SHALL BE WHITE IN COLOR UNLESS OTHERWISE NOTED OR REQUIRED BY ADA OR LOCAL GOVERNING BODIES. 11.SEE SITE PLAN FOR CURB AND GUTTER TYPE. TAPER BETWEEN CURB TYPES-SEE DETAIL. 12.ALL CURB RADII ARE MINIMUM 3' UNLESS OTHERWISE NOTED. 13.CONTRACTOR SHALL REFER TO FINAL PLAT FOR LOT BOUNDARIES, NUMBERS, AREAS AND DIMENSIONS PRIOR TO SITE IMPROVEMENTS. 14.FIELD VERIFY ALL EXISTING SITE CONDITIONS, DIMENSIONS. 15.PARKING IS TO BE SET PARALLEL OR PERPENDICULAR TO EXISTING BUILDING UNLESS NOTED OTHERWISE. 16.ALL PARKING LOT PAINT STRIPING TO BE WHITE, 4" WIDE TYP. 17.BITUMINOUS PAVING TO BE "LIGHT DUTY" UNLESS OTHERWISE NOTED. SEE DETAIL SHEETS FOR PAVEMENT SECTIONS. 18.ALL TREES THAT ARE TO REMAIN ARE TO BE PROTECTED FROM DAMAGE WITH A CONSTRUCTION FENCE AT THE DRIP LINE. SEE LANDSCAPE DOCUMENTS. 19.CONTRACTOR IS RESPONSIBLE TO INSTALL ANY SIDEWALK AND CURBING PER DESIGN PLAN. CONTRACTOR TO VERIFY ALL CURBS AND SIDEWALKS WILL DRAIN PROPERLY IN FIELD CONDITIONS. CONTRACTOR MUST CONTACT THE CIVIL ENGINEER 24-HOURS PRIOR TO ANY CURB AND/OR SIDEWALK INSTALLATION TO REVIEW AND INSPECT CURB STAKES. CONTRACTOR IS RESPONSIBLE FOR ANY CURB OR SIDEWALK REPLACEMENT IF THIS PROCEDURE IS NOT FOLLOWED. CONCRETE PAVEMENT (IF APPLICABLE) AS SPECIFIED (PAD OR WALK) SEE GEOTECHNICAL REPORT FOR AGGREGATE BASE & CONCRETE DEPTHS, WITHIN ROW SEE CITY DETAIL, WITHIN PRIVATE PROPERTY SEE CSG DETAIL. OPERATIONAL NOTES SNOW REMOVAL ALL SNOW SHALL BE STORED ON-SITE OUTSIDE PARKING LOT. WHEN FULL, REMOVAL CO. SHALL REMOVE EXCESS OFF-SITE. TRASH REMOVAL TRASH SHALL BE PLACED IN EXTERIOR TRASH AREA AND REMOVED BY COMMERCIAL CO. WEEKLY. DELIVERIES DELIVERIES SHALL OCCUR AT THE FRONT DOOR VIA STANDARD COMMERCIAL DELIVERY VEHICLES (UPS, FED-EX, USPS). REVISION SUMMARY DATE DESCRIPTION 4/8/2024 CODE COMMENTS 5/8/2024 REVISED LIGHT POLE 7/11/2024 CSI #1 8/1/2024 CSI #2 0 1" = 20'-0" 20'-0"10'-0" N Know what's below. before you dig.Call R C2.0 SITE PLAN OWNER INFORMATION PARK COMMUNITY CHURCH 6805 MINNETONKA BLVD ST LOUIS PARK, MN 55426 JOHN NESS 320-260-1262 JOHN@PARKMN.COM CITY OF ST. LOUIS PARK SITE SPECIFIC NOTES: 1.A PERMIT IS REQUIRED FOR ALL UTILITY WORK IN THE RIGHT OF WAY. CONTACT KAREN WALL AT (952.924.2548) TO OBTAIN A RIGHT OF WAY PERMIT. FEV FUTURE EV CAPABLE CHARGING STATION LOCATION (27 TOTAL) - SEE ELEC'L PLANS EVR EV READY CHARGING STATION LOCATION (2 TOTAL) - SEE ELEC'L PLANS FUTURE CHARGING STATION LOCATION - SEE ELEC'L PLANS. PROVIDE CONDUITS AND CAP IN SIDEWALK AS NECESSARY. SET 2'-8" BEHIND FACE OF CURB. ㄶ 6" W M ( P e r R e c . ) 6" W M ( P e r R e c . ) 9" VCP 9" VCP (Per Rec.) 12" WM (Per Rec.) 12" WM (Per Rec.) 16 " C I P ( P e r R e c . ) 12 " C I P ( P e r R e c . ) 16 " C I P ( P e r R e c . ) 12 " C I P ( P e r R e c . ) (A P u b l i c R / W ) ALLEY (A Public R/W) 9" V C P N89°18'32"E 267.90 S0 1 ° 0 8 ' 5 7 " E 2 3 0 . 9 8 S89°13'28"W 134.18 S01°05'32"E 22.00 S89°13'27"W 134.20 N0 1 ° 0 2 ' 0 6 " W 2 5 3 . 3 7 ID A H O A V E N U E S O U T H (A P u b l i c R / W ) MINNETONKA BOULEVARD (A Public R/W) HA M P S H I R E A V E N U E S O U T H (A P u b l i c R / W ) Existing Garage 2 Story Lap Sided House Foundation Area = 1,678 +/- Sq. Ft. Existing House 2 Story Brick Sided Church with Lookout Basement Foundation Area = 13,411+/- Sq. Ft. Co n c r e t e S i d e w a l k Co n c r e t e S i d e w a l k Concrete Sidewalk Concrete Sidewalk Co n c r e t e S i d e w a l k Co n c r e t e S i d e w a l k Concrete Driveway Co n c r e t e W a l k w a y Concrete Steps Concrete Steps W/ Railing Co n c r e t e W a l k w a y Concrete Step W/ Railing Concrete Access Truncated Dome Truncated Domes Column Column Column Overhang Overhang De c k Wood Step Wood Fence [A] Wood Fence Crosses Property Line Keystone Retaining Wall Monument Sign Wood Fence [B] Bituminous Parking Lot Crosses Property Line Rock Pile 88 . 7 17.9 10 . 7 20.8 6. 1 24.5 2. 5 34.0 2. 4 24.4 35 . 8 19.2 39 . 7 1.0 9. 5 18.3 8. 7 61.8 22 . 0 20.0 11 . 6 17.8 3 1 . 2 21.2 19 . 9 7.1 13 . 6 25.8 26 . 3 40.2 1.3 5. 5 1.4 49 . 8 4. 4 Found 1/2 Inch Open Iron Pipe Found 1/2 Inch Open Iron Pipe PID: 1711721120215 Address: 6805 Minnetonka Boulevard PID: 1711721120016 Address: 3024 Hampshire Avenue South Owner: Poppenhagen Housing Division Sa n . M a i n EXCEPTION AL L E Y Wat. Serv. (Per Rec.) Wat. Serv. (Per Rec.) The N Line of the S 2 Feet of Lot 28, Block 5, "Lenox" The N Line of the S 20 Feet of Lot 10, Block 5, "Lenox" 4. 14" DIM HONEY LOCUST TREE 5. 12" DIM HONEY LOCUST TREE 6. 12" DIM HONEY LOCUST TREE 7. 30 FT TALL ARBORVITAE TREE 1.12" DIM HONEY LOCUST TREE 2. 8FT TALL JUNIPER TREE 12. JUNIPER SHRUB 11. JUNIPER SHRUBS 3. 8 FT TALL JUNIPER TREE 9.WEIGELA SHRUB 10. WEIGELA SHRUB 13. JUNIPER SHRUB 14. JUNIPER SHRUB 15. JUNIPER SHRUB 8. JUNIPER SHRUB 1 - AN 1 - AN 2 - UP1 - PD1 - EK1 - QB 1 - MS 1 - PS3 1 - PD 1 - PS3 1 - QB 1 - RB 1 - RB 1 - AG 8 - AA2 3 - CA2 2 - SM 4 - AA 1 - TN 1 - TN 1 - TN 1 - TN 1 - SM3 1 - SGJ 2 - CA2 2 - SGJ 2 - CA2 2 - SGJ 4 - SGJ 2 - CA2 2 - HL2 4 - AA2 2 - HL2 2 - HL2 5 - HA 1 - AA 1 - TT 1 - TT 1 - AA 7 - RG2 - JM2 3 - HA 4 - TT3 - HA 2 - TN 3 - JM2 3 - JM2 1 - SM3 1 - AA21 - SM 1 - SM 1 - SM 3 - TN 1 - RG 3 - HL2 2 - RG 3 - TT 2 - AA 3 - RG 1 - HL2 1 - TN 2 - HL2 1 - TT 1 - TN 1 - RG 2 - AA 1 - RG 4 - SM3 EVNO PARKINGNO PARKING 5' PARKING SETBACK 30' BLDG. SETBACK 5' P A R K I N G S E T B A C K 5' PARKING SETBACK 5' P A R K I N G S E T B A C K 30 ' B L D G . S E T B A C K 30 ' B L D G . S E T B A C K 30' BLDG. SETBACK 30' BLDG. SETBACK CONSTRUCTION LIMITS CONSTRUCTION LIMITS CONSTRUCTION LIMITS SYMBOL QTY COMMON / BOTANICAL NAME GROUND COVERS 632 sf Decorative Rock Mulch / Decorative Rock Mulch 3/4" Screened Red Limestone, Installed on Geotextile Fabric, 3" deep, w/ landscape eging. Provide Samples. Match existing already in planting beds. 2,646 sf ROCK MAINTENANCE STRIP / ROCK MAINTENANCE STRIP 1.5" DECORATIVE SCREENED ROCK/STONE INSTALLED 3" DEEP OVER GEOTEXTILE FABRIC. PROVIDE EDGING AS SHOWN ON LANDSCAPE PLAN. 1,323 sf SHREDDED CEDAR MULCH 3" DEEP / SHREDDED CEDAR MULCH DOUBLE SHREDDED CEDAR MULCH INSTALLED 4" DEEP ON GRADED, WEED FREE, & PREPARED SOIL. PROVIDE EDGING AS GROUND COVER SCHEDULE L1.0 LANDSCAPE PLAN Civil Engineering Surveying Landscape Architecture 5000 Glenwood Avenue Golden Valley, MN 55422 civilsitegroup.com 612-615-0060 COPYRIGHT CIVIL SITE GROUP INC.c PR O J E C T 2025 ISSUE/SUBMITTAL SUMMARY DATE DESCRIPTION 10/17/2025 CITY SUBMITTAL 12/1/2025 CITY RESUBMITTAL DRAWN BY DK, RB, BN REVIEWED BY DK, RB PROJECT MANAGER DK PROJECT NUMBER 25375 PA R K C O M M U N I T Y C H U R C H RE N O V A T I O N 68 0 5 M I N N E T O N K A B L V D , S T . L O U I S P A R K , M N 5 5 4 2 6 KR A U S - A N D E R S O N C O N S T R U C T I O N C O . 50 1 S E I G H T S T , M I N N E A P O L I S , M N 5 5 4 0 4 LICENSE NO.DATE I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LANDSCAPE ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA. 25821 Robert L. Binder 12/1/2025 LANDSCAPE NOTES: PROPOSED PERENNIAL PLANT SYMBOLS - SEE PLANT SCHEDULE AND PLAN FOR SPECIES AND PLANTING SIZES PROPOSED DECIDUOUS AND EVERGREEN SHRUB SYMBOLS - SEE PLANT SCHEDULE AND PLAN FOR SPECIES AND PLANTING SIZES PROPOSED ORNAMENTAL TREE SYMBOLS - SEE PLANT SCHEDULE AND PLAN FOR SPECIES AND PLANTING SIZES PROPOSED EVERGREEN TREE SYMBOLS - SEE PLANT SCHEDULE AND PLAN FOR SPECIES AND PLANTING SIZES PROPOSED CANOPY TREE SYMBOLS - SEE PLANT SCHEDULE AND PLAN FOR SPECIES AND PLANTING SIZES LEGEND EDGING - SHALL BE COMMERCIAL GRADE, 4" DEPTH ALUMINUM, BLACK OR DARK GREEN IN COLOR, INCLUDE ALL CONNECTORS, STAKES, & ALL APPURTENANCES PER MANUF. INSTALL PER MANUF. INSTRUC./SPECS.SEE SHEET L1.1 FOR PLANTING SCHEDULE PLANTING SEASON SCHEDULE SEASON CONIFEROUS DECIDUOUS REMARKS SPRING PLANTING APRIL 15 - JUNE 15 APRIL 15 - JUNE 15 FALL PLANTING AUGUST 21 - SEPTEMBER 30 AUGUST 15 - NOVEMBER 15 NOTE: ADJUSTMENTS TO PLANTING DATES MUST BE APPROVED IN WRITING BY THE LANDSCAPE ARCHITECT. CONSTRUCTION LIMITS REVISION SUMMARY DATE DESCRIPTION 4/8/2024 CODE COMMENTS 8/1/2024 CSI #2 0 1" = 20'-0" 20'-0"10'-0" N Know what's below. before you dig.Call R 1.ALL EXISTING UTILITY LOCATIONS SHOWN ARE APPROXIMATE. CONTACT "GOPHER STATE ONE CALL" (651-454-0002 OR 800-252-1166) FOR UTILITY LOCATIONS, 48 HOURS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL REPAIR OR REPLACE ANY UTILITIES THAT ARE DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. 2.REFERENCE MULCH SCHEDULE FOR MULCH MATERIALS AND LOCATIONS. 3.ALL TREES SHALL BE MULCHED WITH SHREDDED CEDAR MULCH TO OUTER EDGE OF SAUCER OR TO EDGE OF PLANTING BED, IF APPLICABLE. ALL MULCH SHALL BE KEPT WITHIN A MINIMUM OF 2" FROM TREE TRUNK. 4.IF SHOWN ON PLAN, RANDOM SIZED LIMESTONE BOULDERS COLOR AND SIZE TO COMPLIMENT NEW LANDSCAPING. OWNER TO APPROVE BOULDER SAMPLES PRIOR TO INSTALLATION. 5.PLANT MATERIALS SHALL CONFORM WITH THE AMERICAN ASSOCIATION OF NURSERYMEN STANDARDS AND SHALL BE OF HARDY STOCK, FREE FROM DISEASE, DAMAGE AND DISFIGURATION. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING PLUMPNESS OF PLANT MATERIAL FOR DURATION OF ACCEPTANCE PERIOD. 6.UPON DISCOVERY OF A DISCREPANCY BETWEEN THE QUANTITY OF PLANTS SHOWN ON THE SCHEDULE AND THE QUANTITY SHOWN ON THE PLAN, THE PLAN SHALL GOVERN. 7.CONDITION OF VEGETATION SHALL BE MONITORED BY THE LANDSCAPE ARCHITECT THROUGHOUT THE DURATION OF THE CONTRACT. LANDSCAPE MATERIALS PART OF THE CONTRACT SHALL BE WARRANTED FOR TWO (2) FULL GROWING SEASONS FROM SUBSTANTIAL COMPLETION DATE. 8.ALL AREAS DISTURBED BY CONSTRUCTION ACTIVITIES SHALL RECEIVE 6" LAYER TOPSOIL AND SOD AS SPECIFIED UNLESS OTHERWISE NOTED ON THE DRAWINGS. 9.COORDINATE LOCATION OF VEGETATION WITH UNDERGROUND AND OVERHEAD UTILITIES, LIGHTING FIXTURES, DOORS AND WINDOWS. CONTRACTOR SHALL STAKE IN THE FIELD FINAL LOCATION OF TREES AND SHRUBS FOR REVIEW AND APPROVAL BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 10.ALL PLANT MATERIALS SHALL BE WATERED AND MAINTAINED UNTIL ACCEPTANCE. 11.REPAIR AT NO COST TO OWNER ALL DAMAGE RESULTING FROM LANDSCAPE CONTRACTOR'S ACTIVITIES. 12.SWEEP AND MAINTAIN ALL PAVED SURFACES FREE OF DEBRIS GENERATED FROM LANDSCAPE CONTRACTOR'S ACTIVITIES. 13.PROVIDE SITE WIDE IRRIGATION SYSTEM DESIGN AND INSTALLATION. SYSTEM SHALL BE FULLY PROGRAMMABLE AND CAPABLE OF ALTERNATE DATE WATERING. THE SYSTEM SHALL PROVIDE HEAD TO HEAD OR DRIP COVERAGE AND BE CAPABLE OF DELIVERING ONE INCH OF PRECIPITATION PER WEEK. SYSTEM SHALL EXTEND INTO THE PUBLIC RIGHT-OF-WAY TO THE EDGE OF PAVEMENT/BACK OF CURB. 14.CONTRACTOR SHALL SECURE APPROVAL OF PROPOSED IRRIGATION SYSTEM INCLUDING PRICING FROM OWNER, PRIOR TO INSTALLATION. 1.ENTIRE SITE SHALL BE FULLY IRRIGATED. THE CONTRACTOR SHALL SUBMIT IRRIGATION SHOP DRAWINGS FOR REVIEW AND APPROVAL BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 2.PROVIDE SITE WIDE IRRIGATION SYSTEM DESIGN AND INSTALLATION. SYSTEM SHALL BE FULLY PROGRAMMABLE AND CAPABLE OF ALTERNATE DATE WATERING. THE SYSTEM SHALL PROVIDE HEAD TO HEAD OR DRIP COVERAGE AND BE CAPABLE OF DELIVERING ONE INCH OF PRECIPITATION PER WEEK. SYSTEM SHALL EXTEND INTO THE PUBLIC RIGHT-OF-WAY TO THE EDGE OF PAVEMENT/BACK OF CURB. 3.CONTRACTOR SHALL SECURE APPROVAL OF PROPOSED IRRIGATION SYSTEM INLCUDING PRICING FROM OWNER, PRIOR TO INSTALLATION. 4.SEE MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS FOR IRRIGATION WATER, METER, AND POWER CONNECTIONS. 5.CONTRACTOR TO VERIFY LOCATION OF ALL UNDERGROUND/ABOVE GROUND FACILITIES PRIOR TO ANY EXCAVATION/INSTALLATION. ANY DAMAGE TO UNDERGROUND/ABOVE GROUND FACILITIES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND COSTS ASSOCIATED WITH CORRECTING DAMAGES SHALL BE BORNE ENTIRELY BY THE CONTRACTOR. 6.SERVICE EQUIPMENT AND INSTALLATION SHALL BE PER LOCAL UTILITY COMPANY STANDARDS AND SHALL BE PER NATIONAL AND LOCAL CODES. EXACT LOCATION OF SERVICE EQUIPMENT SHALL BE COORDINATED WITH THE LANDSCAPE ARCHITECT OR EQUIVALENT AT THE JOB SITE. 7.CONTRACTOR SHALL COORDINATE WITH LOCAL UTILITY COMPANY FOR THE PROPOSED ELECTRICAL SERVICE AND METERING FACILITIES. 8.IRRIGATION WATER LINE CONNECTION SIZE IS 1-12" AT BUILDING. VERIFY WITH MECHANICAL PLANS. 9.ALL MAIN LINES SHALL BE 18" BELOW FINISHED GRADE. 10.ALL LATERAL LINES SHALL BE 12" BELLOW FINISHED GRADE. 11.ALL EXPOSED PVC RISERS, IF ANY, SHALL BE GRAY IN COLOR. 12.CONTRACTOR SHALL LAY ALL SLEEVES AND CONDUIT AT 2'-0" BELOW THE FINISHED GRADE OF THE TOP OF PAVEMENT. EXTEND SLEEVES TO 2'-0" BEYOND PAVEMENT. 13.CONTRACTOR SHALL MARK THE LOCATION OF ALL SLEEVES AND CONDUIT WITH THE SLEEVING MATERIAL "ELLED" TO 2'-0" ABOVE FINISHED GRADE AND CAPPED. 14.FABRICATE ALL PIPE TO MANUFACTURE'S SPECIFICATIONS WITH CLEAN AND SQUARE CUT JOINTS. USE QUALITY GRADE PRIMER AND SOLVENT CEMENT FORMULATED FOR INTENDED TYPE OF CONNECTION. 15.BACKFILL ALL TRENCHES WITH SOIL FREE OF SHARP OBJECTS AND DEBRIS. 16.ALL VALVE BOXES AND COVERS SHALL BE BLACK IN COLOR. 17.GROUP VALVE BOXES TOGETHER FOR EASE WHEN SERVICE IS REQUIRED. LOCATE IN PLANT BED AREAS WHENEVER POSSIBLE. 18.IRRIGATION CONTROLLER LOCATION SHALL BE VERIFIED ON-SITE WITH OWNER'S REPRESENTATIVE. 19.CONTROL WIRES: 14 GAUGE DIRECT BURIAL, SOLID COPPER IRRIGATION WIRE. RUN UNDER MAIN LINE. USE MOISTURE-PROOF SPLICES AND SPLICE ONLY AT VALVES OR PULL BOXES. RUN SEPARATE HOT AND COMMON WIRE TO EACH VALVE AND ONE (1) SPARE WIRE AND GROUND TO FURTHEST VALVE FROM CONTROLLER. LABEL OR COLOR CODE ALL WIRES. 20.AVOID OVER SPRAY ON BUILDINGS, PAVEMENT, WALLS AND ROADWAYS BY INDIVIDUALLY ADJUSTING RADIUS OR ARC ON SPRINKLER HEADS AND FLOW CONTROL ON AUTOMATIC VALVE. 21.ADJUST PRESSURE REGULATING VALVES FOR OPTIMUM PRESSURE ON SITE. 22.USE SCREENS ON ALL HEADS. 23.A SET OF AS-BUILT DRAWINGS SHALL BE MAINTAINED ON-SITE AT ALL TIMES IN AN UPDATED CONDITION. 24.ALL PIPE 3" AND OVER SHALL HAVE THRUST BLOCKING AT EACH TURN. 25.ALL AUTOMATIC REMOTE CONTROL VALVES WILL HAVE 3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL UNDERNEATH VALVE AND VALVE BOX. GRAVEL SHALL EXTENT 3" BEYOND PERIMETER OF VALVE BOX. 26.THERE SHALL BE 3" MINIMUM SPACE BETWEEN BOTTOM OF VALVE BOX COVER AND TOP OF VALVE STRUCTURE. IRRIGATION NOTES: ㄷ MTL-1 EB-1 GL-1 STN-1 FLASH-1 MTL-3 MTL-4 CONC-1 STN-1 EX I S T I N G B U I L D I N G H E I G H T 3 7 ' - 5 1 / 2 " NORTH ELEVATION - MATERIAL CLASS % GL-1 MATERIAL ID MATERIAL CLASS SF STN-1 EXISTING GLASS EXISTING CAST STONE EXISTING SURFACE PAINTED METAL EB-1 MTL-2 EXISTING FACE BRICK CLASS 1 2,389 SF CLASS 3 CLASS 1 CLASS 1 207 SF 295 SF 109 SF TOTAL % OF CLASS 1 MATERIALS: 90% TOTAL % OF CLASS 2 MATERIALS: 6% EXISTING PREFINISHED METALMTL-1 CLASS 2 130 SF TOTAL % OF CLASS 3 MATERIALS: 4% PREFINISHED METAL PANELMTL-3 CLASS 2 51 SF PAINTED STEELMTL-4 CLASS 3 14 SF PREFINISHED METAL FLASHINGFLASH-1 CLASS 2 14 SF WEST ELEVATION - MATERIAL CLASS % GL-1 MATERIAL ID MATERIAL CLASS SF STN-1 CONC-1 EXISTING GLASS EXISTING CAST STONE EXISTING PIGMENTED CONCRETE EXISTING PREFINISHED METAL EB-1 MTL-1 EXISTING FACE BRICK CLASS 1 1,853 SF CLASS 2 CLASS 1 CLASS 1 353 SF 503 SF 123 SF CLASS 2 13 SF TOTAL % OF CLASS 1 MATERIALS: 92% TOTAL % OF CLASS 2 MATERIALS: 7% PAINTED STEEL MTL-3 MTL-4 PREFINISHED METAL PANEL CLASS 2 53 SF CLASS 3 13 SF PREFINISHED METAL FLASHINGFLASH-1 CLASS 2 14 SF TOTAL % OF CLASS 3 MATERIALS: 1% FLASH-1 MTL-3 (wrap existing 6x6 tube steel cols w/ MTL-4) MTL-1 GL-1 EB-1 STN-1 STN-1 EX I S T I N G B U I L D I N G H E I G H T 37 ' - 5 1 / 2 " NEW EXTERIOR MATERIAL FINISH SCHEDULE GL-2 MATERIAL ID MATERIAL MANUFACTURER FINISH COLOR LOCATION ALUMINUM WINDOWS FLASHING MTL-3 FLASH-1 METAL PANEL PAC-CLAD PREFINISHED DARK BRONZE ADDITION NOTE: THE "BASIS OF DESIGN" MATERIALS FOR THE PROJECT ARE LISTED ON THE SCHEDULE ABOVE. SEE SPECIFICATIONS FOR ADDITIONAL MATERIAL INFORMATION AND OTHER APPROVE D SUBSTITUTIONS. PRODUCT HIGHLINE S1 PREFINISHED DARK BRONZE ADDITION PREFINISHED BRONZE ADDITION MTL-4 STEEL SHERWIN WILLIAMS PAINTED DARK BRONZE ADDITION 1/8" = 1'-0"AE1.7 2 WEST ELEVATION D E S I G N G R O U P ISSUES & REVISIONS COMMISSION NO: DRAWN BY: CHECKED BY: SHEET 767 N. EUSTIS STREET, SUITE 190 ST. PAUL, MINNESOTA 55114 651.642.9200 WWW.POPEDESIGN.COM POPE DESIGN GROUP NOT F O R C O N S T R U C T I O N 0"1/2"1" TRUE SHEET SCALE DATE 10/20/2025 4:04:27 PM C:\Users\bwicks\Documents\41100-25116_KA - PCC RENOVATION_R25_BWicks_PDG.rvt AE1.7 EXTERIOR ELEVATIONS Checker Author 41100-25116 PARK COMMUNITY CHURCH BUILDING RENOVATION 6805 MINNETONKA BLVD ST. LOUIS PARK, MN 55426 CUP Submission 10-20-25 EXISTING PHOTO: WEST ELEVATION 1/8" = 1'-0"AE1.7 3 NORTH EXTERIOR ELEVATION EXISTING PHOTO: NORTH ELEVATION ZONING CODE EXCERT: TABLE 36-362A ZONING CODE EXCERT: 36-362.g OK MTL-1 MTL-3 GL-1 SN-1 EB-1 FLASH-1 GL-2 MTL-3 FLASH-1 (wrap existing 6x6 tube steel cols w/ MTL-4) (VERTICAL SIDING ) EX I S T I N G B U I L D I N G H E I G H T 37 ' - 5 1 / 2 " AD D I T I O N H E I G H T 17 ' - 1 " PREFINISHED ALUMINUM LETTERS MTL-1 MTL-2 EB-1 GL-1 STN-1 STN-1 EB-1 MTL-1 EX I S T I N G B U I L D I N G H E I G H T 35 ' - 9 1 / 2 " AD D I T I O N H E I G H T 17 ' - 1 " PREFINISHED METAL SIGN -38 SQUARE FEET 6' - 0 " MTL-3 FLASH-1 NEW EXTERIOR MATERIAL FINISH SCHEDULE GL-2 MATERIAL ID MATERIAL MANUFACTURER FINISH COLOR LOCATION ALUMINUM WINDOWS FLASHING MTL-3 FLASH-1 METAL PANEL PAC-CLAD PREFINISHED DARK BRONZE ADDITION NOTE: THE "BASIS OF DESIGN" MATERIALS FOR THE PROJECT ARE LISTED ON THE SCHEDULE ABOVE. SEE SPECIFICATIONS FOR ADDITIONAL MATERIAL INFORMATION AND OTHER APPROVE D SUBSTITUTIONS. PRODUCT HIGHLINE S1 PREFINISHED DARK BRONZE ADDITION PREFINISHED BRONZE ADDITION MTL-4 STEEL SHERWIN WILLIAMS PAINTED DARK BRONZE ADDITION SOUTH ELEVATION - MATERIAL CLASS % GL-1 MATERIAL ID MATERIAL CLASS SF STN-1 CONC-1 EXISTING GLASS EXISTING CAST STONE EXISTING PIGMENTED CONCRETE EXISTING SURFACE PAINTED METAL EB-1 MTL-2 EXISTING FACE BRICK CLASS 1 1,506 SF CLASS 3 CLASS 1 CLASS 1 15 SF 412 SF 19 SF CLASS 2 20 SF TOTAL % OF CLASS 1 MATERIALS: 64% TOTAL % OF CLASS 2 MATERIALS: 35% EXISTING PREFINISHED METALMTL-1 CLASS 2 96 SF TOTAL % OF CLASS 3 MATERIALS: 1% PREFINISHED METAL PANELMTL-3 CLASS 2 979 SF PAINTED STEELMTL-4 CLASS 3 7 SF PREFINISHED METAL FLASHINGFLASH-1 CLASS 2 23 SF GL-2 NEW GLASS CLASS 1 94 SF EAST ELEVATION - MATERIAL CLASS % GL-1 MATERIAL ID MATERIAL CLASS SF STN-1 EXISTING GLASS EXISTING CAST STONE EXISTING SURFACE PAINTED METAL EB-1 MTL-2 EXISTING FACE BRICK CLASS 1 2,982 SF CLASS 3 CLASS 1 CLASS 1 99 SF 195 SF 24 SF TOTAL % OF CLASS 1 MATERIALS: 91% TOTAL % OF CLASS 2 MATERIALS: 8% EXISTING PREFINISHED METALMTL-1 CLASS 2 79 SF TOTAL % OF CLASS 3 MATERIALS: 1% PREFINISHED METAL PANELMTL-3 CLASS 2 194 SF PREFINISHED METAL FLASHINGFLASH-1 CLASS 2 12 SF D E S I G N G R O U P ISSUES & REVISIONS COMMISSION NO: DRAWN BY: CHECKED BY: SHEET 767 N. EUSTIS STREET, SUITE 190 ST. PAUL, MINNESOTA 55114 651.642.9200 WWW.POPEDESIGN.COM POPE DESIGN GROUP NOT F O R C O N S T R U C T I O N 0"1/2"1" TRUE SHEET SCALE DATE 10/20/2025 4:04:26 PM C:\Users\bwicks\Documents\41100-25116_KA - PCC RENOVATION_R25_BWicks_PDG.rvt AE1.6 EXTERIOR ELEVATIONS Checker Author 41100-25116 PARK COMMUNITY CHURCH BUILDING RENOVATION 6805 MINNETONKA BLVD ST. LOUIS PARK, MN 55426 CUP Submission 10-20-25 1/8" = 1'-0"AE1.6 2 SOUTH ELEVATION 1/8" = 1'-0"AE1.6 4 EAST BUILDING ELEVATION EXISTING PHOTO: SOUTH ELEVATION EXISTING PHOTO: EAST ELEVATION EXISTING PHOTO: EAST ELEVATION EXISTING PHOTO: EAST ELEVATION ZONING CODE EXCERT: TABLE 36-362A ZONING CODE EXCERT: 36-362.g OZ Unofficial Minutes Planning commission St. Louis Park, Minnesota January 7, 2026 1. Call to order – 6:00 p.m. Roll Call Members present: Jim Beneke, Mia Divecha (arrived at 6:01 p.m.), Matt Eckholm, John Flanagan, Sylvie Hyman, Tess Machalek, Sarah Strain Members absent: Tom Weber Guests: Joanna Griffith, Pope Design Group Nate Enger, Kraus-Anderson Pastor Andrew Peterson, Park Community Church Edgar Durand, North Central State Regional Council of Carpenters Staff present: Katelyn Champoux, Sean Walther 2. Approval of Minutes – Oct. 8, 2025; Oct. 15, 2025; Nov. 5, 2025 and Dec. 3, 2025. It was moved by Commissioner Beneke, seconded by Commissioner Hyman to approve the Oct. 8, 2025, Oct. 15, 2025, Nov. 5, 2025 and Dec. 3, 2025 minutes. The motion passed 6-0. 3. Hearing 3a. Title: Park Community Church conditional use permit Location: 6805 Minnetonka Blvd. Applicant: Park Community Church Case No: 25-08-CUP Ms. Champoux presented the conditional use permit application for Park Community Church, located at 6805 Minnetonka Boulevard. She explained that staff recommended opening the public hearing but tabling the item until the Jan. 21, 2026 meeting because of an error in the public hearing notice that was mailed to property owners, which listed the incorrect date. A new notice with the correct date was mailed on Jan. 6. Ms. Champoux provided details about the project, explaining that the church proposed to renovate the interior of the sanctuary and community spaces, expand the sanctuary by approximately 500 square feet on the south side of the building (on top of an existing mechanical roof), and remove existing pavement on the north and west sides of the building to replace it with green space. The purpose was to provide more space for the existing congregation and improve accessibility, comfort, and functionality without altering the building's character. She noted that the zoning code requires a conditional use permit for religious institutions in the N-2 zoning district. Although the church's establishment predated this requirement, the proposed site work required the church to come into compliance with city code. 20 Unofficial minutes January 7, 2026 Planning commission Ms. Champoux discussed how the project would remove a significant portion of impervious surface, replacing it with green space and removing two access points onto Minnetonka Boulevard. The planned landscaping would bring the site into compliance with city code, adding 30 trees and 172 shrubs while preserving all existing trees. This would reduce impervious surface coverage from about 75% to 59%. Regarding parking, Ms. Champoux explained that the project would increase sanctuary capacity from approximately 215 to 344 seats, resulting in a parking requirement of 98 spaces (after applying a 15% transit reduction). The church proposed providing 60 off-street parking spaces with 12 potential additional spaces through "proof of parking," plus 13 street parking spaces adjacent to the property. The church requested a reduction of 13 parking spaces to its requirement, which would change the requirement from 98 to 85 spaces. Ms. Champoux noted that the project would also bring the site into compliance with the city's electric vehicle charging infrastructure ordinance and bike parking ordinance, providing 4 parking spaces with EV chargers, 28 spaces with conduit for future chargers, and 12 bike parking spaces (double the requirement). She reported that the project team held a neighborhood meeting on Dec. 3, 2025 with one resident attending who shared general concerns about street parking but did not oppose the project. Commissioner Divecha asked for clarification about the driveway access changes. Ms. Champoux explained that the property currently has five access points and the project would remove two access points on Minnetonka Boulevard and one on Hampshire Avenue South. Commissioner Hyman inquired about the existing shared parking agreement between the church and the community center. Ms. Champoux explained that the informal agreement did not meet city requirements because shared parking agreements need to be permanent and recorded against the property. Commissioner Hyman also asked about bicycle parking plans. Ms. Griffith from Pope Design Group responded that while the specific bike rack design had not been selected, they planned to install functional racks that would exceed the minimum requirement by providing 12 spots instead of the required six. Commissioner Beneke asked if removing parking spots was necessary for the new sanctuary. Mr. Enger from Kraus-Anderson explained that reducing impervious surface helped avoid the need for expensive underground stormwater storage, as there is no stormwater infrastructure currently in that section of Minnetonka Boulevard, which is slated for improvements next fiscal year. He added that the church also desired more green space. Mr. Peterson, Pastor at Park Community Church and St. Louis Park resident, expressed excitement about bringing the historic building up to current code and improving its function for the city and community. He noted that the church, established in 1945, had nearly closed 21 Unofficial minutes January 7, 2026 Planning commission about a decade ago but had been revitalized with a growing congregation that includes many St. Louis Park residents who walk and bike from surrounding neighborhoods. Mr. Durand, a business agent with the North Central State Regional Council of Carpenters, expressed thanks to the Kraus-Anderson team for providing work opportunities for union members. It was moved by Commissioner Strain, seconded by Commissioner Eckholm, to table the Park Community Church CUP and continue the public hearing at the Jan. 21, 2026 meeting. The motion passed 6-0. 4. Other Business 4a. 2026 Work Plan Mr. Walther presented the 2026 work plan that the commission had crafted last year and presented to the city council in November 2025. He explained that the council had asked all boards and commissions to formally approve their recommended plans and council would also review and approve the plans. Mr. Walther outlined the key components of the work plan:  Reviewing planning applications and holding public hearings  Continuing work on phase 2 of the zoning code update, focusing on business district standards, the zoning map for commercial districts, and performance standards  Implementing approved plans for light rail stations and West Excelsior Boulevard  Beginning the 2050 comprehensive plan process, which would be a 2-3 year effort  Broadening participation in planning processes, including the recently implemented stipend for commissioners to reduce barriers to service Mr. Walther explained that if commissioners wanted to propose additions to the work plan during the year, they would need to submit a form to staff, which would then be brought to the commission for discussion and potentially forwarded to the city council for approval. Commissioner Divecha expressed interest in adding a study on parking to the work plan, following up on a discussion from the previous meeting. Mr. Walther agreed to send the form to commissioners. It was moved by Commissioner Divecha, seconded by Commissioner Eckholm to approve the 2026 work plan as proposed by staff. The motion passed 6-0. 5. Communications Future scheduled meeting/event dates:  January 21, 2026 – planning commission regular meeting  February 4, 2026 – planning commission regular meeting  February 25, 2026 – planning commission regular meeting*  March 4, 2026 – planning commission regular meeting *meeting held on Feb. 12, 2026 since Ash Wednesday is Feb. 18, 2026. 22 Unofficial minutes January 7, 2026 Planning commission 6. Adjournment – 6:30 p.m. ______________________________________ ______________________________________ Sean Walther, liaison John Flanagan, chair member These minutes were created with the assistance of a generative AI transcript service, then edited by a staff person. 23 24 Planning commission: Regular meeting Meeting date: January 21, 2026 Agenda item: 3.b 3.b Parkway on 5 preliminary and final plat and variance applications Executive summary Location: 5430 Minnetonka Blvd. Case number: 25-10-S, 25-11-VAR Applicant: Sela Investments, Ltd., LLP Owner: Sela Investments, Ltd., LLP Review deadline: 60 days: February 21, 2026 120 days: April 22, 2026 Recommended motion: Chair to open public hearing, take testimony, and close public hearing. Motion to recommend rescinding previous special permit, conditional use permit, and variance approvals for property located at 5430 Minnetonka Blvd. Motion to recommend approval of the preliminary and final plat of Parkway on 5 located at 5430 Minnetonka Blvd. Motion to recommend approval of a variance to allow a minimum front yard setback of 11 feet instead of the minimum setback of 25 feet in the N-2 zoning district for 5430 Minnetonka Blvd. Summary of requests: The applicant requests the city approve a preliminary and final plat for 5430 Minnetonka Blvd and a variance to the front yard setback to accommodate a proposed low-rise apartment building. The variance would reduce the required setback from a minimum of 25 feet to a minimum of 11 feet. The variance would only apply to the underground parking portion of the development; the above ground portion of the building would meet the 25-foot setback. The subject property is a 1.1-acre site located at the northwest corner of Minnetonka Boulevard and Highway 100. The property is guided RM – medium density residential in the comprehensive plan and zoned N-2. The property is currently vacant but was previously used for a gas station until the Minnesota Department of Transportation acquired the property to facilitate the reconstruction of the Highway 100 off-ramp. The proposed project is a three-story, 33-unit apartment building with a mix of underground and surface parking. The project would also construct a public trail to the east of the property connecting Minnetonka Boulevard to Utica Avenue South. Supporting documents: Site survey, site plan, building elevations Prepared by: Katelyn Champoux, associate planner Reviewed by: Laura Chamberlain, senior planner 25 Regular meeting of January 21, 2026 (Item No. 3.b) Title: Parkway on 5 preliminary and final plat and variance applications Discussion Site information: The subject property is a 1.1-acre site located at the northwest corner of Minnetonka Boulevard and Highway 100. The property is bounded by right-of-way on three sides: Vernon Avenue South to the west, Minnetonka Boulevard to the south, and Highway 100 to the east. The property is currently vacant. Other adjacent uses include single- unit and two-unit dwellings to the north and west, commercial uses to the southwest, and a multi-unit dwelling to the south. Location 5430 Minnetonka Blvd. Site area (acres) 1.1 acres Use Vacant 2040 Future Land Use RM – Medium density residential Zoning N-2 Surrounding land uses North: Single-unit and two-unit dwellings South: Commercial uses, multi-unit dwelling East: Right-of-way West: Single-unit and two-unit dwellings Background: The property was previously used as a gas station with a car wash and retail store until it was acquired by the Minnesota Department of Transportation (MNDOT) to allow the reconstruction of the southbound Highway 100 off-ramp. After completion of the reconstruction project, the city initiated a comprehensive plan amendment and a zoning map amendment for 5430 Minnetonka Blvd. The comprehensive plan amendment changed the future land use from COM – Commercial and ROW – Right of way to RM – Medium density residential and ROW – Right of way. The zoning map amendment changed the zoning of the property from C-1 neighborhood commercial and R-2 two-family residence to R-4 multiple family residence. In 2025, city council updated the zoning code which changed the zoning of the property from R-4 multiple family residence to N-2 neighborhood district. 26 Regular meeting of January 21, 2026 (Item No. 3.b) Title: Parkway on 5 preliminary and final plat and variance applications MNDOT first offered the property to the original owner who decided not to purchase the property. The previous owner would have used the site for the same or similar commercial use which was not permitted under the new land use guiding and zoning district. MNDOT did not offer the property to the city, and the city did not participate in the blind bid auction to purchase the property. The current owner of the property is Sela Investments, Ltd., LLP. Present considerations: The applicant requests the city approve a preliminary and final plat for 5430 Minnetonka Blvd. and a variance to the front yard setback. The variance would reduce the required setback from a minimum of 25 feet to a minimum of 11 feet. The variance would only apply to the underground parking portion of the development. Zoning analysis: Below is a table summarizing the zoning requirements for this project. Further details on some of the requirements are provided after the table. Factor Required Proposed Met? Use Various types of dwelling units, including low-rise apartments Low-rise apartment Yes Height 40 feet 38 feet Yes Building Materials Minimum of 60% Class 1 materials No more than 10% Class 3 materials North: Class I - 72%, Class II - 28% South: Class I - 97% East: Class I - 82%, Class II - 18% West: Class I - 89%, Class II - 11% No Class 3 materials proposed. Yes Off-Street Parking 33 parking spaces 52 total parking spaces (38 underground parking spaces, 14 surface parking spaces) Yes EV charging infrastructure Not required for surface parking lots with 14 spaces or less EV chargers: 8 parking spaces Conduit: 18 parking spaces Yes Bicycle parking 38 bicycle parking spaces 42 bicycle parking spaces Yes Setbacks Front: 25 feet Side: 9 feet Rear: 25 feet Front: 25 feet (above ground), 11 feet (below ground) Side: > 9 feet (both sides) Rear: > 25 feet Yes, with variance approval Designed outdoor recreation area (DORA) 12% 12.4% provided by front patio and amenity deck Yes Landscaping Trees: 33 Shrubs: 329 Trees: 57 Shrubs: 365 Yes 27 Regular meeting of January 21, 2026 (Item No. 3.b) Title: Parkway on 5 preliminary and final plat and variance applications Tree replacement Required to plant 20 inches of trees to replace significant trees removed from the site Landscape plan proposes planting over 100 inches of trees on the property Yes Impervious surface coverage 80% 70% Yes Off-street parking. The zoning code requires 33 parking spaces for the proposed 33-unit apartment building. This includes an additional 5% of the parking requirement for guest parking. The site qualifies for a 15% transit reduction given its proximity to high-frequency bus transit along Minnetonka Boulevard. The project would provide 38 underground parking spaces and 14 surface parking spaces for a total of 52 parking spaces. There is no street parking available adjacent to the property. The proposed project provides sufficient parking to meet the zoning code requirement. Access. The site would have one access point on Vernon Avenue South at the northwest corner of the property. There would be no access to the site from Minnetonka Boulevard, Highway 100, or Utica Avenue South. The Minnesota Department of Transportation restricted direct access to Highway 100 when it sold the property after completing reconstruction of the off- ramp. Hennepin County also supports access to the site from Vernon with no access on Minnetonka Boulevard. Staff requested the applicant locate the driveway as far north on Vernon as possible to mitigate safety concerns from proximity to an intersection. Building materials. The zoning ordinance requires at least 60% class 1 materials, which include materials such as glass and brick, and allows for up to 10% class 3 materials. The project proposes a minimum of 72% class 1 materials on each façade and does not propose using class 3 materials. Height. The height of the proposed building is approximately 38 feet. The building meets the zoning code requirement of a maximum of 40 feet. Yards. The proposed site plan exceeds the required 9-foot side yard setback on the east and west sides of the property and exceeds the required 25-foot rear yard setback on the north side of the property. The above ground portion of the building meets the required 25-foot front yard setback. The applicant is requesting a variance of the front yard setback for the underground portion of the building to be reduced from 25 feet to 11 feet. Electric vehicle supply equipment (EVSE). The zoning code does not require electric vehicle charging infrastructure for surface parking lots with 14 spaces or less. The proposed project includes eight (8) parking spaces served by electric vehicle (EV) chargers. Two (2) spaces in the surface parking lot and six (6) spaces in the underground parking garage. The project would also provide conduit for 18 parking spaces for future installation of EV chargers. Bicycle parking. The zoning code requires 38 bicycle parking spaces for this site. The proposed project would provide 42 bicycle parking spaces, which exceeds the zoning code requirement. 28 Regular meeting of January 21, 2026 (Item No. 3.b) Title: Parkway on 5 preliminary and final plat and variance applications Designed outdoor recreation area (DORA). The project proposes a 5,223 square foot amenity deck on the south side of the building with a pool and several gathering areas for residents, and a 636 square foot patio space adjacent to the building entrance on Vernon Avenue South. This makes up 12% of the total site area, which meets the zoning code requirement. Landscaping. The zoning code requires a minimum of 33 trees and 329 shrubs for this project. The applicant proposes to exceed this requirement by planting 57 trees and 365 shrubs on the site. There are currently four significant trees on the property. This project would remove three significant trees on the west side of the site and preserve one in the northeast corner. The city’s tree preservation ordinance requires the applicant to plant 20 inches of trees to replace the significant trees removed from the site. The landscape plan proposes planting over 100 inches of trees on the property, which satisfies both the landscaping requirements and the tree replacement requirements. Preliminary and final plat analysis: The applicant seeks approval of a preliminary and final plat for Parkway on 5 located at 5430 Minnetonka Blvd. Park and trail dedication: If the preliminary and final plat application is approved, the proposed project will require park and trail dedication. Staff will present recommendations for dedication of land or cash-in-lieu of land to the park and recreation advisory commission (PRAC) on Jan. 21, 2026. No new parks are planned for this area in the comprehensive plan; therefore, cash-in-lieu of land is recommended by staff. The 2025 fee schedule sets the park dedication fee at $1,500 per dwelling unit. Staff estimate the development will owe $49,500 in park dedication fees. The 2025 fee schedule sets the park dedication fee at $225 per unit. Staff estimate the development will owe $7,425 in trail dedication fees. The comprehensive plan shows a proposed trail connecting Minnetonka Boulevard and Utica Avenue South adjacent to 5430 Minnetonka Blvd. The applicant has agreed to install a trail in the Minnesota Department of Transportation right-of-way to the east of the property as part of the project. Staff recommend the park and recreation advisory committee reduce the trail dedication fee by the cost to install the proposed trail. The remaining fee will be paid by the developer. Easements: The lot requires drainage and utility easements along all property lines. Property lines adjacent to right-of-way require ten-foot easements and interior lot lines require five-foot easements. The applicant provided a final plat drawing showing these easements. Staff find the preliminary and final plat meet city requirements with the conditions recommended by staff. Variance analysis: The applicant requests a variance to Section 36-166. Site dimension standards which requires a 25-foot front yard setback. The requested variance would reduce the minimum front yard setback to 11 feet for the underground parking garage. The above-ground portion of the building will meet the 25-foot setback. 29 Regular meeting of January 21, 2026 (Item No. 3.b) Title: Parkway on 5 preliminary and final plat and variance applications Findings: As required by city code, the board of zoning appeals (BOZA) considers the following findings prior to ruling on a variance. City staff provided an analysis of each point below. The applicant submitted a letter explaining the need for the variance. The letter is attached to this staff report. 1. The effect of the proposed variance upon the health, safety, and welfare of the community. The proposed variance does not impact the health, safety, and welfare of the community given the reduced setback only applies to the underground portion of the development. This area would be covered by hardscape and plantings concealing it from passersby. The above ground portion of the building will meet the required 25-foot setback. Staff believe this criterion has been met. 2. Whether or not the request is in harmony with the general purposes and intent of the zoning ordinance. The request is in harmony with the intent of the zoning ordinance given that the project proposes to meet all required setbacks for the above ground portions of the building. The requested variance would also allow the project to accommodate more parking underground rather than increase impervious surface on the site with additional surface parking spaces. Staff believe this criterion has been met. 3. Whether or not the request is consistent with the comprehensive plan. The comprehensive plan encourages a variety of housing styles, sizes, and affordability. The proposed project would add a low-rise apartment building in an area with predominantly single-unit dwellings. The comprehensive plan also aims to increase density along high frequency transit corridors. The project site is located adjacent to a bus stop for a route that runs every 15 minutes at the time of the application submittal. Staff believe this criterion has been met. 4. Whether or not the applicant establishes that there are practical difficulties in complying with the zoning ordinance. Practical difficulty means: a. The proposed use is permitted in the zoning district in which the land is located. A variance can be requested for dimensional items required in the zoning ordinance, including but not limited to setbacks and height limitations. Low-rise apartment dwellings are permitted in the N-2 district. b. The plight of the landowner is due to circumstances unique to the property and not created by the landowner. The topography of the site and the parking restrictions along Minnetonka Boulevard and Vernon Avenue South necessitate the variance request. The topography of the site descends along Minnetonka Boulevard and Vernon Avenue South resulting in an elevation change of approximately 10 feet from the southeast corner to the north and west sides of the site. This elevation change makes it difficult to meet the shadow ordinance in the zoning code without locating the building further south on the site. The applicant chose to shift the building to the 30 Regular meeting of January 21, 2026 (Item No. 3.b) Title: Parkway on 5 preliminary and final plat and variance applications south to meet the shadow ordinance and reduce impacts on neighboring properties to the north. The lack of street parking adjacent to the property means the applicant must accommodate all required parking on site. The variance request allows the applicant to accommodate the requirement while potentially reducing impacts to the adjacent neighborhoods from residents and guest parking on the street further north. It may also deter illegal street parking along Vernon Avenue South which could present significant safety concerns given its proximity to an intersection. c. The variance, if granted, will not alter the essential character of the locality. The variance will allow the construction of a permitted use that minimizes impacts on the adjacent neighborhood by meeting the shadow ordinance and providing off- street parking for residents and guests. The portion of the development impacted by the variance is underground and will not alter the essential character of the street. d. Economic considerations alone do not constitute practical difficulties. Economic considerations are not considered as part of this request. e. Practical difficulties include inadequate access to direct sunlight for solar energy systems. The applicant chose to locate the building further south to limit the shadowing effects on the neighboring buildings to the north. 5. Whether or not there are circumstances unique to the shape, topography, water conditions, or other physical conditions of the property. The topography of the site and the parking restrictions along Minnetonka Boulevard and Vernon Avenue South necessitate the variance request. The topography of the site descends along Minnetonka Boulevard and Vernon Avenue South resulting in an elevation change of approximately 10 feet from the southeast corner to the north and west sides of the site. This elevation change makes it difficult to meet the shadow ordinance in the zoning code without locating the building further south on the site. The applicant chose to shift the building to the south to meet the shadow ordinance and reduce impacts on neighboring properties to the north. Staff believe this criterion has been met. 6. Whether or not the granting of the variance is necessary for the preservation and enjoyment of a substantial property right. The variance would support the construction of a low-rise apartment building which is permitted in the N-2 zoning district. The project also aligns with the RM – Medium density residential land use guiding which allows densities of 18 to 30 units per acre. City council initiated the land use change to RM – Medium density residential in 2021. Staff believe this criterion has been met. 31 Regular meeting of January 21, 2026 (Item No. 3.b) Title: Parkway on 5 preliminary and final plat and variance applications 7. Whether or not the granting of the variance will impair light and air to the surrounding properties, unreasonably increase congestion, increase the danger of fire, or endanger public safety. Granting the requested variance will not impair light and air to the surrounding properties. The site plan proposes a rear setback of approximately 65 feet adjacent to the neighboring property on Vernon Avenue South and approximately 89 feet adjacent to the neighboring property on Utica Avenue South. This is more than double and triple the required 25-foot setback. The intent of this setback is to mitigate light and air impairments on adjacent properties and to reduce the danger of fire. The project will also clean up the contaminated soils on the site during project construction. Staff believe this criterion has been met. 8. Whether or not the granting of the variance will merely serve as a convenience or is it necessary to alleviate a practical difficulty. The variance is necessary to alleviate the practical difficulty created by the topography of the site and lack of street parking. It would allow the applicant to meet the project parking needs with underground parking compared to surface parking which would increase impervious surface on the site. The variance would also allow the building to locate further south on the site to mitigate impacts on adjacent properties. Next steps: The preliminary and final plat application and variance application is tentatively scheduled for city council consideration on Monday, Feb. 2, 2026. Public outreach: A public hearing notice was posted in the Sun Sailor and mailed to property owners within 500 feet of the site. The applicant hosted a neighborhood meeting at Parkway 25 (4015 County Road 25), another building developed by the property owner of 5430 Minnetonka Blvd. Approximately 14 people attended the neighborhood meeting. No attendees expressed opposition to the project. Comments and questions addressed various topics including, but not limited to, outdoor lighting, parking, and site access. Attendees seemed satisfied with responses from the project team and city staff and did not request changes to the proposed site plan. Staff recommendation: Staff recommends the following: Motion to recommend rescinding previous special permit, conditional use permit, and variance approvals for property located at 5430 Minnetonka Blvd. Motion to recommend approval of the preliminary and final plat of Parkway on 5 located at 5430 Minnetonka Blvd., subject to the following conditions: 1. The site shall be developed, used and maintained in accordance with the conditions of the zoning ordinance, approved official exhibits and city code. 2. Construction and staging information will be provided to staff for review and approval before building permits are issued. 3. All new utility service structures shall be buried. 4. Prior to installation of any new signs, the applicant shall submit the necessary sign permits and a site sign plan that shows all existing and proposed signs. No signs will be permitted in public right-of-way. 32 Regular meeting of January 21, 2026 (Item No. 3.b) Title: Parkway on 5 preliminary and final plat and variance applications 5. The final plat shall be recorded within two years after approval of the final plat. If the final plat is not recorded within the two-year period, then the preliminary and final plat shall be considered void, unless a request for a time extension is submitted in writing and approved by the city council. 6. Prior to the city signing and releasing the final plat to the developer for filing with Hennepin County: a. A financial security in the form of cash escrow or letter of credit in the amount of $6,000 shall be submitted to the city to ensure that a signed mylar copy of the final plat is provided to the city ($1,000) and the placement of iron monuments ($5,000). b. A development agreement shall be executed between the city and developer that addresses, at a minimum: i. The installation of all public improvements including, but not limited to sidewalks, modifications to the street, boulevards, and the execution of necessary easements related to such improvements. ii. A performance guarantee in the form of cash escrow or irrevocable letter of credit shall be provided to the City of St. Louis Park in the amount of 1.25 times the estimated costs for the installation of all public improvements, placement of iron monuments at property corners, and landscaping. iii. The applicant shall reimburse the city attorney’s fees in drafting/reviewing such documents as required in the final plat approval. iv. The mayor and city manager are authorized to execute the development agreement. c. The park and trail dedication requirements have been met through land dedication, cash-in-lieu of land, or a combination of the two. 7. Prior to starting any land disturbing activities, the following conditions shall be met: a. Proof of recording the final plat shall be submitted to the city. b. A preconstruction meeting shall be held with the appropriate development, construction, private utility and city representatives. c. All necessary permits shall be obtained. 8. The developer shall comply with the following conditions during construction: a. All city noise ordinances shall be complied with, including that there be no construction activity between the hours of 7 p.m. and 7 a.m. Monday through Friday, and between 7 p.m. and 9 a.m. on weekends and holidays. b. The site shall be kept free of dust and debris that could blow onto neighboring properties. c. Public streets shall be maintained free of dirt and shall be cleaned as necessary. d. The City shall be contacted a minimum of 72 hours prior to any work in a public street. e. Work in a public street shall take place only upon the determination by the city engineer (or designee) that appropriate safety measures have been taken to ensure motorist and pedestrian safety. 33 Regular meeting of January 21, 2026 (Item No. 3.b) Title: Parkway on 5 preliminary and final plat and variance applications f. The developer shall install and maintain chain link security fencing that is at least six feet tall along the perimeter of the site. All gates and access points shall be locked during non-working hours. g. Temporary electric power connections shall not adversely impact surrounding neighborhood service. 9. Prior to the issuance of any permanent certificate of occupancy permit the private utilities, site landscaping and irrigation shall be installed in accordance with the official exhibits. 10. Upon city approval and acceptance of private site improvements, the developer shall provide a one-year warranty in the form of a cash escrow or letter of credit for 25% of the final construction costs of the improvements. 11. In addition to any other remedies, the developer or owner shall pay an administrative fee of $750 per violation of any condition of this approval. Motion to recommend approval of a variance to allow a minimum front yard setback of 11 feet instead of the minimum setback of 25 feet in the N-2 zoning district for 5430 Minnetonka Boulevard, subject to the following conditions: 1. The property shall be developed in accordance with the approved exhibits. 2. The front yard setback shall only apply to the underground portions of the development. The required minimum front yard setback for the above ground portion of the building shall remain 25 feet. 3. The variance is automatically revoked and cancelled if construction of the proposed building is not substantially completed within two years as outlined in city code section 36-38(a)(9). 34 Found Mag Nail Found 1/2 Inch Iron Pipe W/ Cap No. 25718 Found 1/2 Inch Rebar W/ Cap No. 44530 Found 1/2 Inch Open Iron Pipe Found 1/2 Inch Iron Pipe W/ Cap. No. 25710 S89°52'16"E 125.17 N01°49'12"E 27.31 S89°54'35"E 140.34 S1 4 ° 3 7 ' 3 1 " W 2 2 3 . 5 2 N87°50'53"W 210.49 N0 0 ° 0 7 ' 4 4 " E 1 8 1 . 5 8 MINNETONKA BOULEVARD (COUNTY ROAD NO. 5) (A Public R/W) (Width Varies) VE R N O N A V E N U E S O U T H (A P u b l i c R / W ) (W i d t h V a r i e s ) Existing House NO BUILDINGS Co n c r e t e S i d e w a l k Co n c r e t e S i d e w a l k Concrete Bituminous Trail PID: 3102924330124 Address: 5430 Minnetonka Boulevard PID: 3102924330024 Address: 2926 Utica Avenue South Owner: Marnie Lazarus PID: 3102924330019 Address: 2955 Vernon Avenue South Owner: D E & P A Janke Wo o d & C o n c r e t e S o u n d W a l l Area Conveyed in Doc. Nos. A3876997 AND A3876998 N Line of Lot 15, "AUDITOR'S SUBDIVISION NO. 351, HENNEPIN COUNTY, MINNESOTA"N Line of Lot 16, "AUDITOR'S SUBDIVISION NO. 351, HENNEPIN COUNTY, MINNESOTA" NE Corner of Lot 17, "AUDITOR'S SUBDIVISION NO. 351, HENNEPIN COUNTY, MINNESOTA" E Line of LOT 17, "AUDITOR'S SUBDIVISION NO. 351, HENNEPIN COUNTY, MINNESOTA" Found 1/2 Inch Rebar W/ Cap No. 44530 Point 27.3 Feet N'ly of the SE Corner of Lot 17, "AUDITOR'S SUBDIVISION NO. 351, HENNEPIN COUNTY, MINNESOTA" SE C o r n e r o f L o t 1 7 , "A U D I T O R ' S S U B D I V I S I O N N O . 3 5 1 , HE N N E P I N C O U N T Y , M I N N E S O T A " TRACT A S Line Of Lot 17, "AUDITOR'S SUBDIVISIO N N O . 3 5 1 , HENNEPIN COUNTY, MIN N E S O T A " TRACT B TRACT C S Line of Lot 16, "AUDITOR'S SUBDIVISION NO. 351, HENNEPIN COUNTY, MINNESOTA" S Line of Lot 15, "AUDITOR'S SUBDIVISION NO. 351, HENNEPIN COUNTY, MINNESOTA" 27 . 3 0 Chain Link Fence EXCEPTION Ac c e s s R e s t r i c t i o n Pe r D e s c r i p t i o n Truncated Dome (A Z = 1 9 4 ° 3 7 ' 3 1 " ) (AZ=272°09'07") (A Z = 0 0 ° 0 7 ' 4 4 " ) Bench Pl a n t e r Pla n t e r Pla n t e r Pl a n t e r 6" DIP (Per Rec.) 6" D I P ( P e r R e c . ) 6" D I P ( P e r R e c . ) 6" W M ( P e r R e c . ) 9" VCP (Per Rec.) 9 " V C P ( P e r R e c . ) 24" RCP (Per Rec.) 12" R C P ( P e r R e c . ) St o r m S e w e r (P e r R e c . ) Sto r m S e w e r S t o r m S e w e r ( P e r R e c . ) St o r m S e w e r (P e r R e c . ) Truncated Dome Pedestrian Button MI N N E S O T A S T A T E H I G H W A Y N O . 1 0 0 (A P u b l i c R / W ) (W i d t h V a r i e s ) Concrete Driveway UT I C A A V E N U E (A P u b l i c R / W ) (W i d t h V a r i e s ) Wat. Serv. (Per Rec.) DESCRIPTION OF PROPERTY SURVEYED All of Tracts A, B, and C described below: Tract A: Lot 15, except the north 80 feet thereof, and Lot 16, except the north 80 feet thereof, Auditor's Subdivision No. 351, according to the plat thereof on file and of record in the office of the County Recorder in and for Hennepin County, Minnesota; excepting therefrom those parts conveyed to the County of Hennepin in Documents No. A-3876997 and A-3876998, lying westerly, northerly and easterly of the following described line: Beginning at the northeast corner of Lot 17 in said Auditor's Subdivision No. 351; thence southerly to a point on the easterly boundary of said Lot 17, distant 27.3 feet northerly of the southeast corner thereof; thence on an azimuth of 194 degrees 37 minutes 31 seconds for 223.52 feet; thence on an azimuth of 272 degrees 09 minutes 07 seconds for 210.49 feet; thence on an azimuth of 00 degrees 07 minutes 44 seconds for 181.58 feet and there terminating; Tract B: The northerly 80 feet of Lot 16, and the southerly 27.3 feet of Lot 17, Auditor's Subdivision No. 351, according to the plat thereof on file and of record in the office of the County Recorder in and for Hennepin County, Minnesota, lying westerly of the following described line: Beginning at the northeast corner of said Lot 17; thence southerly to a point on the easterly boundary of said Lot 17, distance 27.3 feet northerly of the southeast corner thereof; thence on an azimuth of 194 degrees 37 minutes 31 seconds for 223.52 feet and there terminating; Tract C: The northerly 80 feet of Lot 15, Auditor's Subdivision No. 351, according to the plat thereof on file and of record in the office of the County Recorder in and for Hennepin County, Minnesota, lying easterly of the following described line: Commencing at the northeast corner of Lot 17 in said Auditor's Subdivision No. 351; thence southerly to a point on the easterly boundary of said Lot 17, distant 27.3 feet northerly of the southeast corner thereof; thence on an azimuth of 194 degrees 37 minutes 31 seconds for 223.52 feet; thence on an azimuth of 272 degrees 09 minutes 07 seconds for 210.49 feet to the point of beginning of the line to be described; thence on an azimuth of 00 degrees 07 minutes 44 seconds for 181.58 feet and there terminating; Subject to the following restriction: No access shall be permitted to Trunk Highway No. 100 from the lands herein conveyed. GENERAL SURVEY NOTES 1.Bearings are based on the Hennepin County Coordinate System (1986 Adjustment). 2.Elevations are based on the NGVD 29 Datum. Site Benchmark is the top nut of the fire hydrant located on the north side of Minnetonka Boulevard, approximately 21 feet northeast from the southeast corner of the subject property, as shown hereon . Elevation = 910.02. 3.We have shown the location of utilities to the best of our ability based on observed evidence together with evidence from the following sources: plans obtained from utility companies, plans provided by client, markings by utility companies and other appropriate sources. We have used this information to develop a view of the underground utilities for this site. However, lacking excavation, the exact location of underground features cannot be accurately, completely and reliably depicted. Where additional or more detailed information is required, the client is advised that excavation may be necessary. Also, please note that seasonal conditions may inhibit our ability to visibly observe all the utilities located on the subject property. 4.Site Address: 5430 Minnetonka Boulevard, St. Louis Park, Minnesota 55416. 5.This property is contained in Zone X (area determined to be outside the 0.2% annual chance floodplain) per Flood Insurance Rate Map, Community Panel No. 27053C0353F, effective date of November 4, 2016. 6.The gross land area is 47,349 +/- square feet or 1.087 +/- acres. 7.The names of the adjoining owners of the platted lands, as shown hereon, are based on information obtained from the Hennepin County Interactive Property Map. 8.The fieldwork was completed on 8-14-2025. SURVEY REPORT 1.A boundary determination was not part of the scope of this project. The property description and boundary was obtained from a survey preformed by Cornerstone Land Surveying, Inc., dated 11-8-2024. 2.We have been provided with a Commitment for Title Insurance issued by HomeStead Title LLC as agent for Fidelity National Title Insurance Company, File No. 2500044, dated January 16, 2025, from the client. Said Commitment does not contain documentation of easements affecting the subject property. VICINITY MAP 54 3 0 M i n n e t o n k a B o u l e v a r d St . L o u i s P a r k , H e n n e p i n C o u n t y , M i n n e s o t a 5 5 4 1 6 33 3 W a s h i n g t o n A v e n u e N o r t h , # 2 1 0 , M i n n e a p o l i s , M i n n e s o t a 5 5 4 0 1 DJ R A r c h i t e c t u r e PR O J E C T PROJECT NO.: 25083.00 COPYRIGHT 2025 CIVIL SITE GROUP INC.c REVISION SUMMARY DATE DESCRIPTION V1.0 TOPOGRAPHIC SURVEY 9-12-25 Added Building Heights 1-5-26 Title Commitment .. .. .. .. N 44565 RORY L. SYNSTELIEN LICENSE NO.DATE I HEREBY CERTIFY THAT THIS SURVEY, PLAN, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. 8-18-2025 N CL I E N T Civil Engineering Surveying Landscape Architecture 5000 Glenwood Avenue Golden Valley, MN 55422 civilsitegroup.com 612-615-0060 QA/QC FIELD CREW DRAWN BY REVIEWED BY UPDATED BY TK/VK DS CJ . OVERHEAD UTILITIES GASMAIN SANITARY SEWER STORM SEWER FIBER/COMM. LINE ELECTRIC LINE (RECORD) WATERMAIN ELECTRIC LINE GASMAIN (RECORD) CHAINLINK FENCE LINE Linetype & Symbol Legend CONCRETE SURFACE PAVER SURFACE BITUMINOUS SURFACE GRAVEL/LANDSCAPE SURFACE IRON FENCE LINE GUARDRAIL WATERMAIN (RECORD) SANITARY SEWER (RECORD) STORM SEWER (RECORD) FIBER/COMM. LINE (RECORD) TELEPHONE LINE (RECORD) TELEPHONE LINE SIGN SANITARY MANHOLE STORM MANHOLE CABLE TV BOX TELEPHONE MANHOLE ELECTRIC TRANSFORMER TELEPHONE BOX TRAFFIC SIGNAL GAS METER ELECTRICAL METER WATER MANHOLE WATER VALVE AIR CONDITIONER BOLLARD CATCH BASIN ELECTRIC MANHOLE GAS VALVE FLAG POLE HANDICAP SYMBOL FOUND IRON MONUMENT HYDRANT CAST IRON MONUMENT SET OR TO BE SET IRON MONUMENT FLARED END SECTION POWER POLE UTILITY MANHOLE GUY WIRE CONIFEROUS TREE DECIDUOUS TREE ROOF DRAIN SEWER CLEAN OUT FIRE CONNECTION WELL UTILITY VAULT POST INDICATOR VALVE GAS MANHOLE HAND HOLE FIBER/COMM. MANHOLE MAIL BOX FUEL TANK ELECTRICAL OUTLET SB SOIL BORING LIGHT POLE ACCESS RESTRICTION WOODEN FENCE LINE SATELLITE DISH BUSH/SHRUB 40102001020 SCALE IN FEET ㌵ Found Mag Nail Found 1/2 Inch Iron Pipe W/ Cap No. 25718 Found 1/2 Inch Rebar W/ Cap No. 44530 Found 1/2 Inch Open Iron Pipe Found 1/2 Inch Iron Pipe W/ Cap. No. 25710 S89°52'16"E 125.17 N01°49'12"E 27.31 S89°54'35"E 140.34 S1 4 ° 3 7 ' 3 1 " W 2 2 3 . 5 2 N87°50'53"W 210.49 N0 0 ° 0 7 ' 4 4 " E 1 8 1 . 5 8 MINNETONKA BOULEVARD (COUNTY ROAD NO. 5) (A Public R/W) (Width Varies) VE R N O N A V E N U E S O U T H (A P u b l i c R / W ) (W i d t h V a r i e s ) Existing House NO BUILDINGS Co n c r e t e S i d e w a l k Concrete Bituminous Trail PID: 3102924330124 Address: 5430 Minnetonka Boulevard PID: 3102924330024 Address: 2926 Utica Avenue South Owner: Marnie Lazarus PID: 3102924330019 Address: 2955 Vernon Avenue South Owner: D E & P A Janke Wo o d & C o n c r e t e S o u n d W a l l Area Conveyed in Doc. Nos. A3876997 AND A3876998 N Line of Lot 15, "AUDITOR'S SUBDIVISION NO. 351, HENNEPIN COUNTY, MINNESOTA"N Line of Lot 16, "AUDITOR'S SUBDIVISION NO. 351, HENNEPIN COUNTY, MINNESOTA" HENNEPIN COUNTY, MINNESOTA" E Line of LOT 17, "AUDITOR'S SUBDIVISION NO. 351, HENNEPIN COUNTY, MINNESOTA" Found 1/2 Inch Rebar W/ Cap No. 44530 Point 27.3 Feet N'ly of the SE Corner of Lot 17, "AUDITOR'S SUBDIVISION NO. 351, HENNEPIN COUNTY, MINNESOTA" SE C o r n e r o f L o t 1 7 , "A U D I T O R ' S S U B D I V I S I O N N O . 3 5 1 , HE N N E P I N C O U N T Y , M I N N E S O T A " TRACT A S Line Of Lot 17, "AUDITOR'S SUBDIVISI O N N O . 3 5 1 , HENNEPIN COUNTY, MIN N E S O T A " TRACT B TRACT C S Line of Lot 16, "AUDITOR'S SUBDIVISION NO. 351, HENNEPIN COUNTY, MINNESOTA" S Line of Lot 15, "AUDITOR'S SUBDIVISION NO. 351, HENNEPIN COUNTY, MINNESOTA" 27 . 3 0 Chain Link Fence EXCEPTION Ac c e s s R e s t r i c t i o n Pe r D e s c r i p t i o n Truncated Dome (A Z = 1 9 4 ° 3 7 ' 3 1 " ) (AZ=272°09'07") (A Z = 0 0 ° 0 7 ' 4 4 " ) Bench 6" D I P ( P e r R e c . ) 6" D I P ( P e r R e c . ) 6" W M ( P e r R e c . ) 9" VCP (Per Rec.) 24" RCP (Per Rec.) 12" R C P ( P e r R e c . ) St o r m S e w e r (P e r R e c . ) Sto r m S e w e r S t o r m S e w e r St o r m S e w e r (P e r R e c . ) Truncated Dome Pedestrian Button MI N N E S O T A S T A T E H I G H W A Y N O . 1 0 0 (A P u b l i c R / W ) (W i d t h V a r i e s ) UT I C A A V E N U E (A P u b l i c R / W ) (W i d t h V a r i e s ) Wat. Serv. (Per Rec.) 1311 15 8 16 UP 5 C 18 LOBBY 001 OFFICE 003 ELEC. 009 ENTRY 002 WEST STAIR 050 PACKAGE 004 9' B U I L D I N G S E T B A C K 9' B U I L D I N G S E T B A C K 25' BUILDING SETBACK 25' BUILDING SETBACK GARAGE F L O O R F O O T P R I N T FIRST FLO O R F O O T P R I N T 14 . 0 10.0 14 . 0 8.0 8.0 8. 0 10.0 8.0 CONSTRUCTION LIMITS CONSTRUCTION LIMITS 15 ' P A T I O S E T B A C K 2 8 EV EV 25' BUILDING SETBACK NO PARKING 7. 7 50.0 STORMWATER FILTRATION BASIN ACCESSIBLE PARKING SPACE, INCL. SIGNAGE, STRIPING AND RAMPS MATCH EXISTING, TYP. CONCRETE SIDEWALK, TYP. DRIVE ENTRANCE PER CITY STANDARDS, TYP. HEAVY DUTY CONCRETE PAVEMENT, TYP. HEAVY DUTY CONCRETE PAVEMENT, TYP. B612 C&G, TYP. 3' CURB TAPER, TYP. MATCH EXISTING, TYP. MATCH EXISTING, TYP. BITUMINOUS TRAIL PER CITY STANDARDS, TYP. BITUMINOUS TRAIL PER CITY STANDARDS, TYP. CONCRETE PATIO, TYP. CONCRETE SIDEWALK, TYP. CONCRETE SIDEWALK, TYP. RETAINING WALL, COORD. W/ LANDSCAPE ARCH., TYP. AMENITY DECK, TYP. SEE LANDSCAPE ARCH. PLANS FOR DETAILS CONCRETE SIDEWALK W/ STAIRS AND RAILINGS, TYP. LANDSCAPED AREA, SEE LANDSCAPE ARCH. PLANS FOR DETAILS, TYP. MATCH EXISTING, TYP. MATCH EXISTING, TYP. 24" CONC. VALLEY GUTTER, TYP. RETAINING WALL, COORD. W/ LANDSCAPE ARCH., TYP. CONC. SIDEWALK PER CITY STANDARDS SEE ARCH'L AND LANDSCAPE PLANS FOR POOL FENCE AND GATES DETAILS 4 ELECTRIC VEHICLE (VE) PARKING SPACE, INCL. SIGNAGE & EV CHARGING STATION CONCRETE PATIO, TYP. CONCRETE PATIO, SIDEWALK, STAIRS W/ RAILINGS, TYP. CONC. STAIRS, RAILINGS, & CHEEK WALL, TYP. SEE GRADING PLAN FOR DETAILS CONC. STAIRS, RAILINGS, & CHEEK WALL, TYP. SEE GRADING PLAN FOR DETAILS CONCRETE SIDEWLAK, TYP. CONCRETE SIDEWLAK, TYP. CONC. STAIRS, RAILINGS, & CHEEK WALL, TYP. SEE GRADING PLAN FOR DETAILS MATCH EXISTING, TYP. CONCRETE RAMP PER ADA STANDARDS, TYP. RETAINING WALL, TYP. SEE GRADING PLAN FOR DETAILS CONC. SIDEWALK PER CITY STANDARDS RETAINING WALL, COORD. W/ LANDSCAPE ARCH., TYP. CONCRETE SEAT WALL & AMENITY DECK, TYP. SEE LANDSCAPE ARCH. PLANS FOR DETAILS CONCRETE SEAT WALL AND AMENITY DECK, TYP. SEE LANDSCAPE ARCH. PLANS FOR DETAILS LANDSCAPED AREA, SEE LANDSCAPE ARCH. PLANS FOR DETAILS, TYP. PVMT. STRIPING, TYP. PVMT. STRIPING, TYP.B612 C&G, TYP. PEDESTRIAN RAMP PER ADA STANDARDS, TYP. R 3 . 0 R8.0 R 3 . 0 R3. 0R 3 . 0 R 5 . 0 R3 . 0 R 3 . 0 R3.0 R 1 2 . 0 R16.0 R2. 5 R3. 0 R 8 . 3 R2. 0 R2 0 0 . 0 R10.0 R 1 0 . 0 18 . 0 18 . 0 24 . 0 24 . 2 8. 3 20.0 3' CURB TAPER, TYP. 5. 0 4. 3 4. 3 8.58.5 18 . 0 24 . 0 8. 5 6. 9 24 . 0 8.5 8.5 8.5 25.58.58.5 9. 6 4. 3 7. 0 4.8 4. 5 7. 0 18 . 9 12 . 1 20.8 12.1 5. 0 12 . 2 7. 0 5.0 5. 3 5.017.0 5.0 10.8 5 . 0 5.0 5. 0 17.5 16 . 1 11 . 0 27.6 CONSTRUCTION LIMITS CONSTRUCTION LIMITS PATCH STREET SECTION IN-KIND PER CITY STANDARDS CONTRACTOR IS RESPONSIBLE TO INSTALL ANY SIDEWALK AND CURBING PER DESIGN PLAN. CONTRACTOR TO VERIFY ALL CURBS AND SIDEWALKS WILL DRAIN PROPERLY IN FIELD CONDITIONS. CONTRACTOR MUST CONTACT THE CIVIL ENGINEER 24-HOURS PRIOR TO ANY CURB AND/OR SIDEWALK INSTALLATION TO REVIEW AND INSPECT CURB STAKES. CONTRACTOR IS RESPONSIBLE FOR ANY CURB OR SIDEWALK REPLACEMENT IF THIS PROCEDURE IS NOT FOLLOWED. CONC. PED RAMP PER MNDOT STANDARDS R 5 . 0 COPYRIGHT CIVIL SITE GROUP INC.c PR O J E C T PR E L I M I N A R Y : NO T F O R CO N S T R U C T I O N 2025 ISSUE/SUBMITTAL SUMMARY DATE DESCRIPTION 12/08/2025 CITY SUBMITTAL 12/15/2025 BID SET 1/12/2026 CITY RESUBMITTAL PROJECT MANAGER DAVE KNAEBLE CONTACT NUMBER 612-615-0060 X 703 DRAWN BY KB, DK REVIEWED BY DK PROJECT NUMBER 25083 PA R K W A Y O N 5 54 3 0 M I N N E T O N K A B O U L E V A R D , S T . L O U I S P A R K , M N 5 5 4 1 6 SE L A G R O U P , L L C 49 1 5 W . 3 5 5 T H S T R E E T , # 1 0 2 , S T . L O U I S P A R K , M N 5 5 4 1 6 48776 David J. Knaeble LICENSE NO.DATE I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. 1/12/26 Civil Engineering ° Surveying ° Landscape Architecture 5000 Glenwood Avenue Golden Valley, MN 55422 civilsitegroup.com 612-615-0060 OW N E R SITE LAYOUT NOTES: SITE PLAN LEGEND (SHEETS C2.0-C2.2): TRAFFIC DIRECTIONAL ARROW PAVEMENT MARKINGS SIGN AND POST ASSEMBLY. SHOP DRAWINGS REQUIRED. HC = ACCESSIBLE SIGN NP = NO PARKING FIRE LANE ST = STOP CP = COMPACT CAR PARKING ONLY PROPERTY LINE CURB AND GUTTER-SEE NOTES (T.O.) TIP OUT GUTTER WHERE APPLICABLE-SEE PLAN LIGHT DUTY BITUMINOUS PAVEMENT (IF APPLICABLE). SEE GEOTECHNICAL REPORT FOR AGGREGATE BASE & WEAR COURSE DEPTH, SEE DETAIL. HEAVY DUTY BITUMINOUS PAVEMENT (IF APPLICABLE). SEE GEOTECHNICAL REPORT FOR AGGREGATE BASE & WEAR COURSE DEPTH, SEE DETAIL. CONSTRUCTION LIMITS TO SPECIALTY PAVEMENT (IF APPLICABLE) - PROVIDE BID FOR THE FOLLOWING OPTIONS, INCLUDE VARIATIONS OF BASE MATERIAL AND OTHER NECESSARY COMPONENTS. 1. STAMPED & COLORED CONCRETE 2. CONCRETE PAVERS MAKERS, COLORS, MODELS, & PATTERN TO BE INCLUDED IN SHOP DRAWING SUBMITTAL PRIOR TO CONSTRUCTION. CITY OF ST. LOUIS PARK SITE SPECIFIC NOTES: 1.SIGNAGE WILL BE APPROVED THROUGH A SEPARATE SIGN PERMIT. PROJECT MAY HAVE UP TO 200 SF OF SIGNAGE WITH A MAXIMUM OF 100 SF FOR ONE SIGN FACE AND MAX HEIGHT OF 25 FT FOR A PYLON SIGN. 2.PROPOSED PYLON SIGNAGE ON THE CHIPOTLE SITE CANNOT BE USED FOR SIGNAGE FOR THE BUSINESSES ON THE NEIGHBORING PROPERTY. SIGNAGE FOR THAT PROPERTY MUST BE LOCATED ON THE PROPERTY ITSELF. 3.OUTDOOR LIGHTING FIXTURES TO HAVE DIMMING CONTROL SYSTEM OR DIMMING DRIVERS TO MEET CITY CODE OF 1.0 FC AVERAGE BETWEEN THE HOURS OF 10PM AND 6AM. ACCESSIBILITY ROUTE ARROW (IF APPLICABLE) DO NOT PAINT. 1.ALL EXISTING UTILITY LOCATIONS SHOWN ARE APPROXIMATE. CONTACT "GOPHER STATE ONE CALL" (651-454-0002 OR 800-252-1166) FOR UTILITY LOCATIONS, 48 HOURS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL REPAIR OR REPLACE ANY UTILITIES THAT ARE DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. 2.CONTRACTOR SHALL VERIFY LOCATIONS AND LAYOUT OF ALL SITE ELEMENTS PRIOR TO BEGINNING CONSTRUCTION, INCLUDING BUT NOT LIMITED TO, LOCATIONS OF EXISTING AND PROPOSED PROPERTY LINES, EASEMENTS, SETBACKS, UTILITIES, BUILDINGS AND PAVEMENTS. CONTRACTOR IS RESPONSIBLE FOR FINAL LOCATIONS OF ALL ELEMENTS FOR THE SITE. ANY REVISIONS REQUIRED AFTER COMMENCEMENT OF CONSTRUCTION, DUE TO LOCATIONAL ADJUSTMENTS SHALL BE CORRECTED AT NO ADDITIONAL COST TO OWNER. ADJUSTMENTS TO THE LAYOUT SHALL BE APPROVED BY THE ENGINEER/LANDSCAPE ARCHITECT PRIOR TO INSTALLATION OF MATERIALS. STAKE LAYOUT FOR APPROVAL. 3.THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION, INCLUDING A RIGHT-OF-WAY AND STREET OPENING PERMIT. 4.THE CONTRACTOR SHALL VERIFY RECOMMENDATIONS NOTED IN THE GEO TECHNICAL REPORT PRIOR TO INSTALLATION OF SITE IMPROVEMENT MATERIALS. 5.CONTRACTOR SHALL FIELD VERIFY COORDINATES AND LOCATION DIMENSIONS & ELEVATIONS OF THE BUILDING AND STAKE FOR REVIEW AND APPROVAL BY THE OWNERS REPRESENTATIVE PRIOR TO INSTALLATION OF FOOTING MATERIALS. 6.LOCATIONS OF STRUCTURES, ROADWAY PAVEMENTS, CURBS AND GUTTERS, BOLLARDS, AND WALKS ARE APPROXIMATE AND SHALL BE STAKED IN THE FIELD, PRIOR TO INSTALLATION, FOR REVIEW AND APPROVAL BY THE ENGINEER/LANDSCAPE ARCHITECT. 7.CURB DIMENSIONS SHOWN ARE TO FACE OF CURB. BUILDING DIMENSIONS ARE TO FACE OF CONCRETE FOUNDATION. LOCATION OF BUILDING IS TO BUILDING FOUNDATION AND SHALL BE AS SHOWN ON THE DRAWINGS. 8.THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OR SAMPLES AS SPECIFIED FOR REVIEW AND APPROVAL BY THE ENGINEER/LANDSCAPE ARCHITECT PRIOR TO FABRICATION FOR ALL PREFABRICATED SITE IMPROVEMENT MATERIALS SUCH AS, BUT NOT LIMITED TO THE FOLLOWING, FURNISHINGS, PAVEMENTS, WALLS, RAILINGS, BENCHES, FLAGPOLES, LANDING PADS FOR CURB RAMPS, AND LIGHT AND POLES. THE OWNER RESERVES THE RIGHT TO REJECT INSTALLED MATERIALS NOT PREVIOUSLY APPROVED. 9.PEDESTRIAN CURB RAMPS SHALL BE CONSTRUCTED WITH TRUNCATED DOME LANDING AREAS IN ACCORDANCE WITH A.D.A. REQUIREMENTS-SEE DETAIL. 10.CROSSWALK STRIPING SHALL BE 24" WIDE WHITE PAINTED LINE, SPACED 48" ON CENTER PERPENDICULAR TO THE FLOW OF TRAFFIC. WIDTH OF CROSSWALK SHALL BE 5' WIDE. ALL OTHER PAVEMENT MARKINGS SHALL BE WHITE IN COLOR UNLESS OTHERWISE NOTED OR REQUIRED BY ADA OR LOCAL GOVERNING BODIES. 11.SEE SITE PLAN FOR CURB AND GUTTER TYPE. TAPER BETWEEN CURB TYPES-SEE DETAIL. 12.ALL CURB RADII ARE MINIMUM 3' UNLESS OTHERWISE NOTED. 13.CONTRACTOR SHALL REFER TO FINAL PLAT FOR LOT BOUNDARIES, NUMBERS, AREAS AND DIMENSIONS PRIOR TO SITE IMPROVEMENTS. 14.FIELD VERIFY ALL EXISTING SITE CONDITIONS, DIMENSIONS. 15.PARKING IS TO BE SET PARALLEL OR PERPENDICULAR TO EXISTING BUILDING UNLESS NOTED OTHERWISE. 16.ALL PARKING LOT PAINT STRIPING TO BE WHITE, 4" WIDE TYP. 17.BITUMINOUS PAVING TO BE "LIGHT DUTY" UNLESS OTHERWISE NOTED. SEE DETAIL SHEETS FOR PAVEMENT SECTIONS. 18.ALL TREES THAT ARE TO REMAIN ARE TO BE PROTECTED FROM DAMAGE WITH A CONSTRUCTION FENCE AT THE DRIP LINE. SEE LANDSCAPE DOCUMENTS. 19.CONTRACTOR IS RESPONSIBLE TO INSTALL ANY SIDEWALK AND CURBING PER DESIGN PLAN. CONTRACTOR TO VERIFY ALL CURBS AND SIDEWALKS WILL DRAIN PROPERLY IN FIELD CONDITIONS. CONTRACTOR MUST CONTACT THE CIVIL ENGINEER 24-HOURS PRIOR TO ANY CURB AND/OR SIDEWALK INSTALLATION TO REVIEW AND INSPECT CURB STAKES. CONTRACTOR IS RESPONSIBLE FOR ANY CURB OR SIDEWALK REPLACEMENT IF THIS PROCEDURE IS NOT FOLLOWED. 20.FINISH GRADING FOR HARDSCAPE AREAS IE. PARKING LOTS, CURBS, SIDEWALKS SHALL BE WITHIN 0.05 FEET. ADA AREAS MUST COMPLY WITH REQUIREMENTS ON PLANS AND ADA REGULATIONS. TOLERANCE WITHIN ADA AREAS IS 0.00 FEET DISCUSS ANY DEVIATIONS WITH ENGINEER PRIOR TO CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR ANY CURB, SIDEWALK AND/OR PAVEMENT REPLACEMENT THAT DOES NOT MEET TOLERANCE/ADA REQUIREMENTS. CONCRETE PAVEMENT (IF APPLICABLE) AS SPECIFIED (PAD OR WALK) SEE GEOTECHNICAL REPORT FOR AGGREGATE BASE & CONCRETE DEPTHS, WITHIN ROW SEE CITY DETAIL, WITHIN PRIVATE PROPERTY SEE CSG DETAIL OPERATIONAL NOTES SNOW REMOVAL ALL SNOW SHALL BE STORED ON-SITE OUTSIDE PARKING LOT IN OPEN LANDSCAPED AREAS. WHEN FULL, REMOVAL CO. SHALL REMOVE EXCESS OFF-SITE. TRASH REMOVAL TRASH SHALL BE PLACED IN EXTERIOR TRASH AREA AND REMOVED BY COMMERCIAL CO. WEEKLY. DELIVERIES DELIVERIES SHALL OCCUR AT THE FRONT DOOR VIA STANDARD COMMERCIAL DELIVERY VEHICLES (UPS, FED-EX, USPS). REVISION SUMMARY DATE DESCRIPTION C2.0 SITE PLAN 0 1" = 20'-0" 20'-0"10'-0" N Know what's below. before you dig.Call R OWNER INFORMATION SELA INVESTMENTS LTD, LLP 4915 WEST 35TH STREET, SUITE 102 ST, LOUIS PARK, MN 55416 PAZ SELA 612-290-7632 PAJJS@AOL.COM HEAVY DUTY CONCRETE PAVEMENT (IF APPLICABLE) AS SPECIFIED. SEE GEOTECHNICAL REPORT FOR AGGREGATE BASE & CONCRETE DEPTHS, WITHIN ROW SEE CITY DETAIL, WITHIN PRIVATE PROPERTY, SEE CSG DETAIL ㌶ LEVEL 1 100' -0" LEVEL 2 112' -1 7/8" LEVEL 3 123' -9 3/4" ROOF TRUSS BEARING 133' -10 7/8" 1' - 0 " 1' - 1 0 " 1' - 6 3 / 4 " 10 ' - 1 1 / 8 " 11 ' - 7 7 / 8 " 12 ' - 1 7 / 8 " T.O. HIGH PARAPET 138' -3 5/8" W4 W10 W9 W9 W4 W9 W9 W9W9W10 PR I N C I P A L B U I L D I N G H E I G H T 38 ' - 3 5 / 8 " W10 A352 D1 A352 B1 211917 T.O. LOW PARAPET 137' -3 5/8" 15 2 3 11 13 1 6 5 10 4 9 T.O. ROOF SHEATING 135' -5 5/8" 22 23 LEVEL 1 100' -0" LEVEL 2 112' -1 7/8" LEVEL P1 88' -8" LEVEL 3 123' -9 3/4" ROOF TRUSS BEARING 133' -10 7/8" T.O. HIGH PARAPET 138' -3 5/8" 1' - 0 " 1' - 1 0 " 1' - 6 3 / 4 " 10 ' - 1 1 / 8 " 11 ' - 7 7 / 8 " 12 ' - 1 7 / 8 " 11 ' - 4 " W4 W4 W4W4 W4 W4 W4 A350 B1 A350 D1 A350 E1 49 ' - 7 5 / 8 " SF06 W5W1 W1 W9W4 W4 W9 SF07SF07 SF07 SF04 SF05 F W4 T.O. LOW PARAPET 137' -3 5/8" K W1 W1 20 14 8 1819 11 81 17 6 5 1 4 2 B T.O. ROOF SHEATING 135' -5 5/8" 22 23 W5 80 3 LEVEL 1 100' -0" LEVEL 2 112' -1 7/8" LEVEL 3 123' -9 3/4" ROOF TRUSS BEARING 133' -10 7/8" T.O. HIGH PARAPET 138' -3 5/8" A300 B1L 1' - 0 " 1' - 1 0 " 1' - 6 3 / 4 " 10 ' - 1 1 / 8 " 11 ' - 7 7 / 8 " 12 ' - 1 7 / 8 " W9 W9 W9W9 W8 PR I N C I P A L B U I L D I N G H E I G H T 38 ' - 3 5 / 8 " W8 A352 A1 T.O. LOW PARAPET 137' -3 5/8" K 9 2 3 5 6 4 11 13 1 T.O. ROOF SHEATING 135' -5 5/8"22 23 LEVEL 1 100' -0" LEVEL 2 112' -1 7/8" LEVEL 3 123' -9 3/4" ROOF TRUSS BEARING 133' -10 7/8" T.O. HIGH PARAPET 138' -3 5/8" 1' - 0 " 1' - 1 0 " 1' - 6 3 / 4 " 10 ' - 1 1 / 8 " 11 ' - 7 7 / 8 " 12 ' - 1 7 / 8 " PR I N C I P A L B U I L D I N G H E I G H T 38 ' - 3 5 / 8 " M T.O. LOW PARAPET 137' -3 5/8" 9 2 11 1 5 4 T.O. ROOF SHEATING 135' -5 5/8"22 23 EX T E N T S O F G A R A G E ( B E L O W G R A D E ) 10' - 0" 25'-0" SETBACK FROM PROPERTY LINE SEE PLAN VARIES UNIT PATIO LEVEL 1 100' -0" LEVEL 2 112' -1 7/8" LEVEL 3 123' -9 3/4" ROOF TRUSS BEARING 133' -10 7/8" T.O. HIGH PARAPET 138' -3 5/8" A351 C1 A350 F11 A300 B3 1' - 0 " 1' - 1 0 " 1' - 6 3 / 4 " 10 ' - 1 1 / 8 " 11 ' - 7 7 / 8 " 12 ' - 1 7 / 8 " W9 W4 W9 W9 W4 W9 W10 W4 W9 W4 W9 W9 W4 W9 W10 W4 PR I N C I P A L B U I L D I N G H E I G H T 38 ' - 3 5 / 8 " W10 SF10SF08SF09 W9 A351 A1 T.O. LOW PARAPET 137' -3 5/8" 4 1 4 2 11 10 81 13 5 7 T.O. ROOF SHEATING 135' -5 5/8" 22 23 6 15 3 EXTERIOR MATERIALS SIDING 1 -METAL PANEL MFR: ALUCOBOND CLASSIC COLLECTION COLOR: STATUARY BRONZE SIDING 2 -FIBER CEMENT PANEL MFR: CERACLAD PANEL: CAST STRIPE VERITCAL ORIENTATION COLOR: PEARL SIDING 3 -FIBER CEMENT WOOD-LOOK PANEL MFR: CERACLAD PANEL: URBAN CEDAR COLOR: ESPRESSO BRICK MFR: BELDEN BRICK COMPANY NORMAN BRICK COLOR: TUMBLEWEED VELOUR DARK BRICK COLOR MFR: BELDEN BRICK COMPANY NORMAN BRICK COLOR: SIENNA BLEND VELOUR BURNISH BLOCK COLOR: TO MATCH TUMBLEWEED VELOUR BRICK COMPOSITE WINDOW MFR: ANDERSEN 100 SERIES EXT COLOR: DARK BRONZE INT COLOR: SLIDING DOORS MFR: ANDERSEN 100 SERIES EXT COLOR: DARK BRONZE INT COLOR: STOREFRONT COLOR: DARK BRONZE Cop y r i g h t 2 0 2 5 D J R A r c h i t e c t u r e , I n c . C B AD 4 3 2 1 333 Washington Ave N, Suite 210 Minneapolis, Minnesota 55401 612.676.2700 www.djr-inc.com Issue:Date: Project #: Date: Drawn by: Checked by: NOT FOR CONSTRUCTION N O T F O R C O N S T R U C T I O N EF 5 A200 EXT E R I O R E L E V A T I O N S 54 3 0 M I N N E T O N K A B O U L E V A R D , S A I N T L O U I S P A R K , M N 23-007.00 12.08.2025 KH MS PAR K W A Y O N 5 1/8" = 1'-0"B3 EXTERIOR ELEVATION -SOUTH (2) 1/8" = 1'-0"E1 EXTERIOR ELEVATION -WEST KEYNOTES - EXTERIOR Note # Note 1 FACE BRICK VENEER 2 BRICK SOLDIER COURSE 3 ROWLOCK COURSE HEADER 4 PREFINISHED METAL PANEL 5 FIBER CEMENT PANEL SIDING (PEARL) 6 FIBER CEMENT WOOD-LOOK PANEL SIDING (ESPRESSO) 7 PREFINISHED METAL PARAPET CAP - COLOR TO MATCH FIBER CEMENT 8 KNOX BOX 9 CAST STONE SILL 10 FIBERGLASS SLIDING DOOR 11 PREFINISHED ALUMINUM BALCONY W/ GLASS PANELS 12 PATIO SWING DOOR 13 PREFINISHED METAL MAGIC-PAK GRILL 14 BUILDING SIGNAGE 15 HOSE BIB 16 EXPOSED CMU COLOR TO MATCH ADJACENT BRICK 17 ELEVATOR OVERRUN 18 FIRE DEPARTMENT CONNECTION 19 ELECTRONIC ACCESS SYSTEM 20 GAURDRAIL 21 GARAGE DOOR 22 FIBER CEMENT PANEL REVEAL 23 C CHANNEL - COLOR TO MATCH FIBER CEMENT PANEL 80 ALUMINUM STOREFRONT 81 COMPOSIT WINDOW MATERIAL CALCS - SOUTH Material Type Material Class Area Percentage FIBER CEMENT PANEL CLASS I 2,643 SF 41% GLAZING CLASS I 2,422 SF 37% BRICK CLASS I 804 SF 12% WOOD-LOOK PANEL CLASS I 437 SF 7% 6,306 SF 97% PREFINISHED METAL CLASS II 207 SF 3% 207 SF 3% Grand total 6,512 SF 100% MATERIAL CALCS - WEST Material Type Material Class Area Percentage BRICK CLASS I 494 SF 12% FIBER CEMENT PANEL CLASS I 2,146 SF 51% GLAZING CLASS I 1,043 SF 25% WOOD-LOOK PANEL CLASS I 35 SF 1% 3,718 SF 89% METAL PANEL CLASS II 312 SF 7% PREFINISHED METAL CLASS II 168 SF 4% 480 SF 11% Grand total 4,198 SF 100% 1/8" = 1'-0"C1 EXTERIOR ELEVATION -WEST COURTYARD 1/8" = 1'-0"A1 EXTERIOR ELEVATION -WEST SE BUMP-OUT 1/8" = 1'-0"E3 EXTERIOR ELEVATION -SOUTH (1) CITY REVIEW 12.08.2025 37 LEVEL 1 100' -0" LEVEL 2 112' -1 7/8" LEVEL P1 88' -8" LEVEL 3 123' -9 3/4" ROOF TRUSS BEARING 133' -10 7/8" T.O. HIGH PARAPET 138' -3 5/8" 11 ' - 4 " 12 ' - 1 7 / 8 " 11 ' - 7 7 / 8 " 10 ' - 1 1 / 8 " 1' - 6 3 / 4 " 1' - 1 0 " 1' - 0 " W10 W9 W9 W4 W9 W4 W9 W9W4W9W4W9 W2 W10 W10 W2 W9 W4 W9 W4 W9 W3 W3 W9 W9 W9 49 ' - 7 5 / 8 " A353 C1 A353 D1 A353 F1 SF01 SF01 SF01 SF01 SF01 SF02 SF03 21 19 17 1A300 B3 A350 A1 T.O. LOW PARAPET 137' -3 5/8" 4 4 10 13 11 81 21 2 1 5 7 17 T.O. ROOF SHEATING 135' -5 5/8" 22 23 80 4 10 11 1 20 93 LEVEL 1 100' -0" LEVEL 2 112' -1 7/8" LEVEL P1 88' -8" LEVEL 3 123' -9 3/4" ROOF TRUSS BEARING 133' -10 7/8" T.O. HIGH PARAPET 138' -3 5/8" A300 B1 W9 W9 W4 W9 W4 W4 W4W4W9W7W4W4W7W4W9 W9 W9 W4 W7 W4 W4 W7 W9 W4 W4 1' - 0 " 1' - 1 0 " 1' - 6 3 / 4 " 10 ' - 1 1 / 8 " 11 ' - 7 7 / 8 " 12 ' - 1 7 / 8 " 11 ' - 4 " 49 ' - 7 5 / 8 " W9W4 W4W9 W9 W4W9 W9 A352 F1 A353 A1 W4 W4 L F C AMA352 A1 T.O. LOW PARAPET 137' -3 5/8" 4 5 11 1 2 3 81 12 10 T.O. ROOF SHEATING 135' -5 5/8" 11 16 EXTERIOR MATERIALS SIDING 1 -METAL PANEL MFR: ALUCOBOND CLASSIC COLLECTION COLOR: STATUARY BRONZE SIDING 2 -FIBER CEMENT PANEL MFR: CERACLAD PANEL: CAST STRIPE VERITCAL ORIENTATION COLOR: PEARL SIDING 3 -FIBER CEMENT WOOD-LOOK PANEL MFR: CERACLAD PANEL: URBAN CEDAR COLOR: ESPRESSO BRICK MFR: BELDEN BRICK COMPANY NORMAN BRICK COLOR: TUMBLEWEED VELOUR DARK BRICK COLOR MFR: BELDEN BRICK COMPANY NORMAN BRICK COLOR: SIENNA BLEND VELOUR BURNISH BLOCK COLOR: TO MATCH TUMBLEWEED VELOUR BRICK COMPOSITE WINDOW MFR: ANDERSEN 100 SERIES EXT COLOR: DARK BRONZE INT COLOR: SLIDING DOORS MFR: ANDERSEN 100 SERIES EXT COLOR: DARK BRONZE INT COLOR: STOREFRONT COLOR: DARK BRONZE 1/8" = 1'-0"C3 EXTERIOR ELEVATION -NORTH 1/8" = 1'-0"C1 EXTERIOR ELEVATION -EAST MATERIAL CALCS - EAST Material Type Material Class Area Percentage BRICK CLASS I 561 SF 14% FIBER CEMENT PANEL CLASS I 1,538 SF 39% GLAZING CLASS I 1,152 SF 29% 3,250 SF 82% METAL PANEL CLASS II 584 SF 15% PREFINISHED METAL CLASS II 135 SF 3% 720 SF 18% Grand total 3,970 SF 100% MATERIAL CALCS - NORTH Material Type Material Class Area Percentage BRICK CLASS I 1,019 SF 12% FIBER CEMENT PANEL CLASS I 3,145 SF 36% GLAZING CLASS I 2,129 SF 24% 6,293 SF 72% METAL PANEL CLASS II 1,924 SF 22% PREFINISHED METAL CLASS II 515 SF 6% 2,439 SF 28% Grand total 8,732 SF 100% Cop y r i g h t 2 0 2 5 D J R A r c h i t e c t u r e , I n c . C B AD 4 3 2 1 333 Washington Ave N, Suite 210 Minneapolis, Minnesota 55401 612.676.2700 www.djr-inc.com Issue:Date: Project #: Date: Drawn by: Checked by: NOT FOR CONSTRUCTION N O T F O R C O N S T R U C T I O N EF 5 A201 EXT E R I O R E L E V A T I O N S 54 3 0 M I N N E T O N K A B O U L E V A R D , S A I N T L O U I S P A R K , M N 23-007.00 12.08.2025 KH MS PAR K W A Y O N 5 KEYNOTES - EXTERIOR Note # Note 1 FACE BRICK VENEER 2 BRICK SOLDIER COURSE 3 ROWLOCK COURSE HEADER 4 PREFINISHED METAL PANEL 5 FIBER CEMENT PANEL SIDING (PEARL) 6 FIBER CEMENT WOOD-LOOK PANEL SIDING (ESPRESSO) 7 PREFINISHED METAL PARAPET CAP - COLOR TO MATCH FIBER CEMENT 8 KNOX BOX 9 CAST STONE SILL 10 FIBERGLASS SLIDING DOOR 11 PREFINISHED ALUMINUM BALCONY W/ GLASS PANELS 12 PATIO SWING DOOR 13 PREFINISHED METAL MAGIC-PAK GRILL 14 BUILDING SIGNAGE 15 HOSE BIB 16 EXPOSED CMU COLOR TO MATCH ADJACENT BRICK 17 ELEVATOR OVERRUN 18 FIRE DEPARTMENT CONNECTION 19 ELECTRONIC ACCESS SYSTEM 20 GAURDRAIL 21 GARAGE DOOR 22 FIBER CEMENT PANEL REVEAL 23 C CHANNEL - COLOR TO MATCH FIBER CEMENT PANEL 80 ALUMINUM STOREFRONT 81 COMPOSIT WINDOW CITY REVIEW 12.08.2025 38 Planning commission: Study session Meeting date: January 21, 2026 Agenda item: 1 1 Zoning Code Update - phase 2 – parking standards Recommended Action: No action at this time. Consider direction on how parking minimums should be addressed through the Zoning Code Update phase 2 and beyond. Background: The planning commission discussed the topic of parking standards as part of the study session on Sept. 9, 2025. Based on the discussion, staff identified the following approach to parking minimums within phase 2 of the zoning code update:  The reduced parking minimum standards that currently apply to the MX-2 district will be expanded to all new MU districts  The Historic Walker Lake area will get rid of parking minimums altogether  There is no change to parking minimums proposed for residential uses This approach was presented to the city council, along with other elements of the zoning code update, on Nov. 10, 2025. City council members commented that they liked seeing reduced parking requirements and that the Historic Walker Lake area made for good “testing grounds” of eliminating parking minimums. On Dec. 3, commissioner Hyman requested to revisit the topic of parking minimums, as not all commissioners were present for the initial discussion. Commissioners raised the following questions for staff, requesting a study session specifically to talk about parking minimums in zoning:  What is the history of parking minimum standards in St. Louis Park and where did those standards come from?  What are other communities doing about parking minimums?  What are some resources for research and best practices on the topic? At the study session, staff will present historical context for the standards St. Louis Park has today, along with examples of how other communities are handling parking minimums through zoning. Commissioners will engage in a discussion about parking, which includes challenges the city is facing and goals that could be pursued. Recommendation: Staff recommends proceeding with the approach presented to city council for the zoning code update and also including the parking minimum topic in the 2050 Comprehensive Plan process to facilitate community participation and input and to build the policy foundation needed for next steps. Prepared by: Laura Chamberlain, senior planner Reviewed by: Gary Morrison, zoning administrator Attachments:  Official minutes, planning commission, study session, Sept. 9, 2025  Official minutes, city council, study session, Nov. 10, 2025 39 Official Minutes Planning commission September 3, 2025 6:00 p.m. Planning commission Study Session Members present: Jim Beneke, Mia Divecha, Matt Eckholm, John Flanagan, Sarah Strain, Tom Weber Members absent: Sylvie Hyman Staff present: Gary Morrison Guests: Jeff Miller and Beth Richmond from HKGi presented the report. 1. Zoning Code Update phase 2 – updates to Article V Special Provisions Mr. Miller stated HKGi will present the results of the community survey, which closed at the end of August, and provide an analysis of Article V Special Provisions of the zoning code, including the following topics: parking & loading facilities, landscaping, screening, signage, and community survey results. Mr. Miller stated that the survey questions focused on the neighborhood corridors and commercial spaces and received 240 responses. He reported in detail on the survey results, which are included in the staff report. Commissioner Beneke asked about offset parking . Ms. Richmond stated it relates to restrictions in parking, with the limit of 300 feet from a residential structure and 500 feet from a non-residential structure. Commissioner Divecha added she was pleased to see that more people are not asking for more parking in the survey results. Commissioner Eckholm stated it is difficult to narrow in on what sort of parking issues are a legitimate concern and what are a scarcity mindset from the community, as many issues are emotionally charged. Commissioner Eckholm stated that more parking requirements in certain areas of the city may be a harder sell. Ms. Richmond asked the commissioners if there are parking issues that the planning commission has heard about or areas that should be focused on. Mr. Morrison noted there are many city-owned and maintained parking lots around the city, particularly in the Walker Lake area. He added, over time the city would like to get away from owning and maintaining these parking lots. Docusign Envelope ID: 058E2A99-A545-4108-881E-1FC55784E398 40 Official Minutes Planning commission study session Sept. 3, 2025 2 Commissioner Weber stated it would be best to limit parking . Commissioner Divecha asked what the argument for mandating parking is. Ms. Richmond stated that the argument is that businesses will not provide enough parking on their own, and then it becomes an issue if people park on the street and elsewhere. She continued, it is at the multifamily apartments where enough parking has not been provided. Mr. Morrison noted the city has street permit parking around the schools and on Vallacher Ave., and near the Ellipse Apartments. Ms. Richmond stated that, for financing requirements, many times developers must show they have parking for apartment buildings. Commissioner Eckholm stated that the conversation always goes back to there not being enough parking. He stated he is less concerned about restaurants and small businesses, but noted larger commercial businesses will provide ample parking if they feel it is pertinent to their business. Commissioner Weber stated the goals should be to add flexibility to the requirements and let businesses open. Commissioner Eckholm added also, because delivery has increased, many businesses do not need 9 parking spaces any longer, similar to the Chipotle development , which is order and pick up through the drive-through. Commissioner Eckholm stated he would like to take the parking restrictions out of the Walker Lake district. He added that the area around The Block is very busy with parking around the restaurant. He stated it is only a problem here because people are used to parking in front of where they are going. Commissioner Weber asked if, in the Miracle Mile area, there is a way to have a parking code for the neighborhood, and cut parking by 30% by 2050, and if that should be the vision to work toward. Commissioner Eckholm added that if the county is not going to shrink the road, then we need to put the building up right next to the road to make it denser, so drivers go slower. He added, however, that he is not sure how realistic the idea is, especially because Miracle Mile bumps up to neighborhoods on the south side of Excelsior. Mr. Morrison stated the city can work with the residential owners to create alleyways behind their homes to also include parking behind businesses, rather than in front. He added, however, that it comes down to what property owners are willing to do. Docusign Envelope ID: 058E2A99-A545-4108-881E-1FC55784E398 41 Official Minutes Planning commission study session Sept. 3, 2025 3 Commissioner Divecha stated that when we require minimums, we are blocking off areas of the city for cars over people. She stated she understands the issue, but it constrains what we want someplace like the Walker Lake area to be. Commissioner Weber stated there are two parking spaces for each classroom at the high school and asked what those spaces are based on. Ms. Richmond stated that these are for two spaces for each classroom for teachers and support staff. Mr. Miller stated he notes the commissioners are interested in expanding parking at Walker Lake to other areas, there is interest in having new construction have more flexibility at Walker Lake, also, and so parking is not as restrictive there. Commissioner Strain asked about what exists in the parking code and if there is flexibility, and if it has to be a permanent easement. She asked if there is a way to get at some of these issues, expand shared parking options, and rely more on traffic reports. Mr. Morrison stated the city does have the ability to be flexible with parking standards, but a CUP that goes before council and documentation that provides a reason for a reduction in parking. He stated CUP is not, however, required to be flexible, and added there is flexibility in transit areas within the code, and within a certain distance to light rail . He added that this is a policy issue for the planning commission and the city council to decide. Commissioner Divecha asked about the CUP. Ms. Richmond stated that currently, off-site parking requires a CUP. Ms. Richmond asked about non-residential areas. She asked if the planning commission would want to adjust or eliminate non-residential. Commissioner Eckholm stated that for M2 and M3, for more mixes and uses in the bigger areas, there are more single-use buildings, and if we encourage this, the mix of uses does not occur. Mr. Morrison stated that in Walker Lake, the parking helps to encourage mixed use. Commissioner Eckholm stated he would like to get rid of minimums for parking where the commission can. Commissioner Weber stated that this discussion by the planning commission will need to be presented to the city council and then agreed upon by at least 4 council members to move forward. Commissioner Divecha stated the planning commission needs to take this further, though. Commissioner Weber stated that the planning commission will have more opportunities to respond to parking. Docusign Envelope ID: 058E2A99-A545-4108-881E-1FC55784E398 42 Official Minutes Planning commission study session Sept. 3, 2025 4 Mr. Morrison added that working to fine-tune parking is a big first step. Chair Flanagan asked about timelines and how soon we can see if it works, so the discussions can keep going. Mr. Morrison stated that staff will update the city council in October regarding parking . Ms. Richmond explained alternative landscaping, special design features, such as rain gardens, native landscaping, and more creative ways of keeping property . She stated this section is very subjective and does not provide guidance vs. regular requirements. Mr. Morrison stated that the intent is to show that landscaping is not always only trees . Commissioner Weber noted the city is losing tree canopy and asked if there are ways to be creative on replacement through the zoning code. Ms. Richmond noted that the screening discussion will move into its own separate section and will be looked at within the parking lots. She stated that signage cannot be regulated now because of free speech, but no big changes to signs are allowed. She added that super graphic signs and murals will also be reviewed, while being content -neutral. Ms. Richmond stated the next discussion with the planning commission will be in October to discuss procedures, definitions, and general zoning provisions . Mr. Miller stated there will be more discussions and that parking may move out of this process for further in-depth discussion. Commissioner Eckholm agreed. Commissioner Divecha stated she would be interested in some case studies on parking as well, with more robust discussion. The following comments submitted by Commissioner Hyman were distributed to the commissioners. From: Sylvie Hyman <sylvishawn7@gmail.com> Sent: Wednesday, September 3, 2025 4:15 PM To: Laura Chamberlain <LChamberlain@stlouisparkmn.gov>; Gary Morrison GMorrison@stlouisparkmn.gov>; Sean Walther <SWalther@stlouisparkmn.gov> Subject: Sylvie's Comments for 9/3 Planning Commission Study Session CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Hi Laura, Sean, and Gary, My apologies for getting this in so late. Here are my comments for tonight's meeting. I'm very sad to be missing this one! Docusign Envelope ID: 058E2A99-A545-4108-881E-1FC55784E398 43 Official Minutes Planning commission study session Sept. 3, 2025 5 Parking structures- we should not encourage developers to build parking structures by including density bonuses for underground parking. These are more costly and all of that cost is passed on to those who can least afford it. We should look at eliminating mandates everywhere we can and keeping them in strategically where they won't pass costs onto non-drivers. Incentivise underground parking structures by limiting the impervious surfaces they are allowed to build at grade for the purpose of parking. Residential parking mandates should be 100% eliminated. Everyone needs a home but not everyone needs to park a car. What benefits individuals is unique to the individual so by mandating something that only benefits a certain group we are punishing non- drivers. Non-drivers are people who can't afford car ownership, are too young for a driver's license, people with disabilities that prevent them from driving, or people who choose not to drive for environmental reasons, convenience, or cost. Passing unnecessary costs on to non-drivers is wrong. Mandates make it less affordable to build homes while the region desperately needs more homes. Infill development is crucial for preventing more damaging sprawl, especially in first ring suburbs like St. Louis Park . Many of the survey responses expressed desires for small businesses and medium density development, but these types of development are stifled by parking mandates. Mandates for all other uses should also be reduced or eliminated. For places where minimums are kept, there should be alternatives offered, like the installation of bicycle parking or parklets in place of mandated parking spaces. Looking more specifically at the zoning map, anything within a quarter mile of the light rail stations should have no minimum parking requirements. All parking spaces should be accompanied by tree planting, native rain gardens, or other ecological features to offset the environmental harms done by the additional impervious surface and car use. Bicycle parking requirements should also be eliminated and replaced with incentives/programs to support the installation of secure, easy to use bicycle parking facilities. Also the city should use revenue from the sale of city owned lots to build bike parking in public right of way. Sec 36-361 Off street Parking (a) Purpose states that the purpose of regulating off street parking is to "prevent congestion" and for "safety", but excess parking encourages more driving which is the main cause of congestion on our streets. They also make spaces less safe by putting more cars in spaces where people should be. Rather than requiring parking, we should require safety features and environmental mitigation to offset the harms and threats from driving and parking. Question responses: 1. (Survey) Will the city be doing more engagement leading up to the public hearing(s) for this? How do the percentages of homeowners/renters who responded correspond to the percentages of homeowners/renters who live in SLP? Docusign Envelope ID: 058E2A99-A545-4108-881E-1FC55784E398 44 Official Minutes Planning commission study session Sept. 3, 2025 6 2. (CUP for off-site parking) Need for the permits should be eliminated or reduced with the mandates. 3. (Min parking caused issues) It's hard to know what could have been built if we hadn't built so much parking. The main issue I see is lack of tree canopy and greenspace due to excessive amounts of land being devoted to parking lots. 4. (Table 36-361b applied to MU, C-1, other districts) Parking should not be required, but if it must be then we should require an amount proportional to the amount of people who DRIVE to the place, not the amount of people we expect to BE at those places. 5. (Existing landscaping requirements) I'm no expert, but my personal opinion is that the current requirements are overly complicated. I feel like there should be a simpler way to get the benefits we're looking for when it comes to supporting habitats for pollinators, cleaning up the watershed, adding/maintaining shade trees, etc. I think that providing incentives and support (like the native plant sale) for these elements are much more beneficial than complex mandates that most people won't follow and likely won't be enforced. 6. (ideas to improve/make less subjective) Everywhere it has single and 2 unit dwellings exempted should be extended to all N1 and maybe even N2. Sec 36-364 (d) (3) Landscaping requirements Change from trees per dwelling unit to trees per square footage of dwelling space. Eliminate fence requirements unless they are needed to protect people from some hazard. Find better ways to protect people from hazards or eliminate the hazards. Best regards, Sylvie Hyman sylvishawn7@gmail.com @sylvie-h.bsky.social 561) 809-3059 Future scheduled meeting/event dates: September 17, 2025 – planning commission regular meeting October 8, 2025 – planning commission study session* October 15, 2025 – planning commission regular meeting November 5, 2025 – planning commission regular meeting Meeting held on October 8, 2025 (Yom Kippur is October 1 and 2) Adjournment – 8:00 p.m. Sean Walther, liaison John Flanagan, chair member Docusign Envelope ID: 058E2A99-A545-4108-881E-1FC55784E398 45 Official minutes City council study session St. Louis Park, Minnesota Nov. 10, 2025 The meeting convened at 6:34 p.m. Council Members present: Mayor Nadia Mohamed, Margaret Rog, Lynette Dumalag, Sue Budd, Tim Brausen, Yolanda Farris, Paul Baudhuin Council Members absent: none Staff present: City manager (Ms. Keller), senior planner (Ms. Chamberlain), community development director, interim building and energy director (Ms. Barton), zoning administrator Mr. Morrison), economic development manager (Ms. Monson), planning manager (Mr. Walther) Guests: Jeff Miller, Consultant with HKGi Discussion items 1. Boards and Commissions check in with the city council: Planning Commission/Board of Zoning Appeals Mr. Flanagan, planning commission chair, presented the report. The planning commission and the board of zoning appeals (BOZA) are statutory boards composed of the same members. The planning commission serves in an advisory capacity to the city council on matters where authority is granted to the council by state law or the city charter. These matters include land use, comprehensive planning, zoning, platting, street modifications and other general planning issues. Additionally, the board of zoning appeals reviews and makes recommendations on matters referred to it or as required under the zoning ordinance. Mr. Flanagan reviewed the commission’s accomplishments in 2025 and highlighted the 2026 work plan for the planning commission, including: 1. Planning and zoning application review: Review planning and zoning applications submitted to the city; hold public hearings to help inform commission recommendations and BOZA and council decisions. 2. Zoning code update: Review and recommend changes to the zoning code to better reflect the city’s strategic priorities and implement the comprehensive plan goals, policies and strategies. Phase 2 – Commercial, office, business park, and industrial districts and related zoning map changes and performance standards. In the first quarter of 2026, the planning commission will hold a public hearing and recommend changes to the zoning map and non-residential district zoning standards and performance standards. 46 Study session minutes -2- Nov. 10, 2025 3. Implementation of Arrive + Thrive: St. Louis Park Gateways Plan: Review the online implementation tracker and get annual updates on progress. 4. 2050 Comprehensive Plan: Identify how the outcomes of Vision 4.0 can be woven throughout the comprehensive planning process, expected to last from 2026-2028. Review selected regional planning documents as they apply to the city. Review policies and strategies amended in the comprehensive plan and review iterations of the comprehensive plan chapters. Monitor overall progress until adopted. 5. Broaden participation: Identify strategies to broaden and reduce barriers to public participation. Have a joint meeting with other commission(s) on a topic of shared interest/responsibility. Hold a planning commission meeting at an off-site location to foster community relationships. e.g., study sessions with topics of general interest, development project tours, etc.) Help recruit community members with diverse experiences to apply for vacancies on boards and commissions, task forces, committee, or other volunteer opportunities. Mr. Flanagan noted future ideas: Water conservation and water recycling: Explore ways to encourage reduced water use, capture and reuse of storm water, and protect groundwater resources. Housing analysis: Explore setting policy targets for different housing types in the city based on the present inventory and unmet demand and promote homeownership opportunities as well as inclusionary housing goals. Council Member Budd noted the 2025 work plan related to addressing requests within a 60-day window and asked how big a challenge that is. Ms. Chamberlain stated that staff are very diligent about maintaining that 60-day window. City staff can initiate an extension of an additional 60-days for a total of up to 120 days, while the applicant can approve an extension after that time. Council Member Rog asked whether the planning commission allows remote comments and if any progress has been made in that space, adding she is supportive. Ms. Chamberlain stated that the practice has not been added and that the item will continue onto the 2026 work plan. Mr. Flanagan added that the planning commission accepts emailed comments. Council Member Brausen asked whether stipends were extended for the planning commission. Ms. Chamberlain confirmed that stipends were extended. Regarding remote comments, Council Member Brausen stated that he assumes there are state laws supporting remote community engagement measures. Ms. Keller confirmed this is true and noted that staff capacity to work with remote comments is another consideration, recalling that technology use and integration during meetings has been an issue in the past. 47 Study session minutes -3- Nov. 10, 2025 Council Member Brausen stated that he supports the planning commission’s inclusion of water conservation and water recycling in their future ideas. He suggested that a joint meeting with the Environmental Sustainability Commission might be warranted. The city council regularly accesses the planning commission minutes. He stated the questions, comments and recommendations made during planning commission meetings are wonderful. Council Member Brausen complimented the commission to keep up the great work. Council Member Budd asked for more information on the visit to Union Park Flats. She asked if residents were in attendance. Mr. Flanagan stated the meeting was open to the public but that no residents attended. Mr. Flanagan shared that the visit included of a tour of the development along with an overview of the building and a question-and-answer session. Council Member Rog asked what is working well for the planning commission and if there are any gaps or opportunities. Mr. Flanagan stated that while the planning commission gets direction from the city council, it can be difficult at times to know if they are aligned with the council on zoning and other issues, adding some extra guidance or input would be helpful. Council Member Rog stated that the planning commission and staff do excellent work. Council Member Dumalag noted future plans related to housing analysis, adding that it will be interesting to see if the policies put forth manifest themselves in physical spaces. Council Member Dumalag referenced a recent vote on a development for a Chipotle in the Knollwood area, and how it related to accessibility. As the city population is getting older, the accessibility issue will become more apparent and she wanted to flag that for the planning commission. Mr. Flanagan agreed and stated the planning commission will continue to work on accessibility needs as projects that come forward. Council Member Baudhuin thanked Mr. Flanagan for his work and the planning commission minutes, noting that he appreciates the volume of work being done. Council Member Budd asked if the planning commission is fully staffed. Mr. Flanagan stated yes and noted a new commissioner was recently appointed as well as a new youth member. Mayor Mohamed thanked Mr. Flanagan for his presentation and for all the work the planning commission does. 2. Zoning code update discussion Mr. Morrison stated that the planning commission provided direction to staff at five study sessions conducted since May of 2025. The feedback resulted in the draft summarized in the staff report. The amendments to the zoning code propose updates to the administration procedures and zoning district regulations. It also proposes updates to the special provisions, which include parking, landscaping, signage, and architectural design. The amendment will reformat the ordinance into the format established with the first phase of the update approved earlier this year. 48 Study session minutes -4- Nov. 10, 2025 Mr. Morrison stated public outreach included a project webpage, community-wide emails and articles in the Park Perspective. Staff conducted a community survey from May 22, 2025, to Aug. 24, 2025. The survey was available in the languages of English, Spanish and Somali. There were 240 respondents (239 in English, one in Spanish). Staff is also conducting a second survey focused on the business community, and a third phase of engagement is planned for January 2026 that will include open houses and online opportunities. Comments and questions from the city council related to major changes noted below: Replacing the Office, Business Park and C-1 Neighborhood Commercial zoning districts with mixed-use districts Changing the zoning map district boundaries Utilizing density and height bonuses to achieve policy objectives Determining uses that need council review Reducing parking minimum requirements Revising the public hearing process for variances Council Member Budd asked for an explanation of C2 and Mixed-Use (MU-2) zoning. Mr. Morrison stated “big box” retail is intended to be kept in the B1 district – general business. Mr. Morrison added that some smaller retail businesses in the Knollwood area or on Excelsior Boulevard could move into MU-1 or 2. Council Member Rog asked if the zoning codes will move into the municipal code. Mr. Walther stated that the zoning codes information could be moved into that format at some point. Council Member Brausen asked for clarification on where the school properties are marked on the maps. Mr. Morrison stated that schools are in the neighborhood zoned areas. Council Member Rog asked if there was anything dramatically different in the zoning map proposal. Mr. Morrison stated no, adding it was not staff’s intent to change anything dramatically. The biggest changes are what we discussed with the changes to the zoning districts and integrating the results of the Arrive and Thrive plan. Mr. Morrison added that the map reflects placing zoning districts with similar heights adjacent to N1 and N2 districts. Council Member Budd asked how much existing density bonuses in the zoning code have been used. Mr. Walther stated only one project has used the density bonuses, but it did not include the available inclusionary housing bonus. The district design requirements have been a barrier, the point system for bonuses has been too complex, and the points awarded for inclusionary housing have not been enough incentive. Council Member Rog stated she has concerns about community response to many changes. The council should be cautious in how this would come about in the community, and aware of other ways to meet goals more comfortably through community expectations. Council Member Baudhuin added that there are uncertainties already with the potential change of existing one-story buildings being replaced or added onto to be up to three stories tall, adding that he would like to research potential density or height bonuses further before 49 Study session minutes -5- Nov. 10, 2025 proceeding, asking if it could be added later. Mr. Walther stated yes, noting that bonuses in the MU-1 district could be delayed and discussed further by the planning commission and city council at a later date. Council Member Budd stated that no matter how compelling residents' arguments might be, the city council cannot deny if all conditions are met. Mr. Walther clarified council cannot decide to deny based only on neighborhood opposition but can choose to deny if the issue does not meet the standards of the conditional use permit (CUP). Council Member Brausen asked which zone Union Flats would be included in. Mr. Walther stated it’s currently in N2, but it would fit best in MU1 or MU2 because of its proximity to light rail transit. Council Member Rog asked if density bonuses are predetermined now. Mr. Walther stated it is a complicated points system now, but staff is looking to simplify it and set a standard to make the system easier to understand. Council Member Rog stated the Green Building policy is an investment that has a payoff and is the kind of incentive that is beneficial for building owners. Council Member Dumalag stated she feels the Green Building policy is at risk with the federal administration. Council Member Budd stated she prefers to keep the Green Building policy. Council Member Baudhuin added that incentivizing something that is already a financial benefit to developers gives him pause. Mayor Mohamed asked about parking standards and if the existing standards would remain in the Walker Lake district only or be district-wide. Mr. Morrison stated the existing parking standards would apply to the MU-1, MU-2 and MU-3 districts only, and no parking minimums for non-residential uses would be required in the Walker Lake district only. Council Member Baudhuin stated he likes the parking standards at the Walker Lake district and making places less focused on parking and more on walkability in general. Council Members Farris, Budd and Dumalag agreed. Council Member Dumalag stated that while she is in favor, crosswalk use is also important to walkability. Council Member Rog asked what the difference is between allowing any use to occupy any building and having no parking minimums. Mr. Walther stated that in Walker Lake, there were existing buildings that were redone for other uses, so parking was not required and on-street parking was accepted. Parking was a barrier but doing away with parking minimums has been positive for the Walker Lake district. 50 Study session minutes -6- Nov. 10, 2025 Council Member Rog asked if parking minimums might present a challenge in other parts of the city. Mr. Morrison stated challenges may result from a broader use of on-street parking. Council Member Rog stated she is pleased with parking in the Walker Lake district. Council Member Rog stated with regards to planning commission and city council approval of projects, the planning commission minutes sometimes reflect comments and input that are outside the scope of the project, but improves the project with small recommendations, and there is a benefit when the process is adhered to. Council Member Rog added that there is an awareness factor as well, with projects going through administratively, and staff should make sure the council is aware. Mr. Morrison added that he understands the benefit of additional eyes on projects is helpful. Council Member Dumalag agreed with Council Member Rog’s comments and noted that with the parking ramp in Beltline, there was feedback and public engagement involved, and it is helpful to hear both from staff and from the council regarding expectations. Council Member Baudhuin shared that he appreciates examples to help clarify projects. Mr. Morrison stated that staff can structure the draft ordinance so that if there are limits that trigger a CUP, they can be put into specific use standards rather than using a table that applies citywide. Mr. Walther stated the staff will work with the council’s input to be ready for community engagement. Mr. Morrison noted that staff is looking at the variance process and noted several changes with notices and mailings that would be sent to adjacent properties only. Mr. Walther noted that this would streamline the formal variance process. Council Member Budd asked about the mailed notice and the public hearing. Mr. Morrison stated the public hearing would still be held and comments would be taken; this would also be written into the ordinance. Mr. Morrison stated council’s comments will go to the planning commission at their Dec. 3, 2025 meeting. After the open house events, the draft of the ordinance would next be brought to the planning commission for review before scheduling the public hearing. Staff asked for council to provide input on the policy question, does the city council support the staff and planning commission sharing the proposed changes to the zoning districts, performance standards, and administrative procedures with the public in January 2026? The council agreed with the policy question. Written Reports 3. Conveyance of EDA-owned land to the city – all wards. 51 Study session minutes -7- Nov. 10, 2025 Council Member Dumalag asked if the conveyance of EDA-owned land to the city includes the dump site. Mr. Walther confirmed this. 4. Sewer access charge (SAC) credit policy Council Member Rog stated that this summer, some businesses in the city received notice that their Sewer Availability Charge (SAC) fees were increasing. Mr. Walther stated there was concern because some businesses were adding outdoor seating and their fees would change as a result of expansion. He stated this is a one-time fee only and not ongoing. However, it is a significant fee, so there were some concerns from businesses. Council Member Budd stated that a few businesses she spoke to said they did not want to go through the process, so they stopped offering patio seating because of the fees. Mr. Walther stated that staff reached out to the business and explained the process and the Met Council component. Council Member Rog asked if usage shrinks, could there be any reversal of the fees. Ms. Barton stated yes; that is where the credits come in and the fees are paid only once by the business. 5. Development update Q4 2025 Council Member Brausen stated that there are several projects with construction that is not progressing because of financial issues. Council Member Brausen asked about the Arlington East and West project being dropped. Mr. Walther stated it was dropped because the preliminary plat had expired and noted multiple extensions were given. The plat approval process will have to be undertaken again. 6. Minnetonka Boulevard twin homes update – Ward 1 Communications/meeting check-in (verbal) The meeting adjourned at 8:07 p.m. Melissa Kennedy, city clerk Nadia Mohamed, mayor 52